5.5.3 Function Description
5.5.3.1 Definition of Time Period
Time period is the minimum time period unit of Access Options.
Whole system can be defined with maximum 50 time periods. And
7 time regions (i.e. one week) can be set in each time period. Each
time region is effective time period in 24 hours of a day. Each user
can own maximum 3 time periods. Relationships among these three
time periods are “OR”. It is effective as long as the time to verify
that can meet one of these three time periods. Each time period
format of time period is HH:MM-HH:MM and its format is
according to 24-hour mode and accurate to minute. This option can
only be configured by the User Administrator or the Super
Administrator.
End-time less than start-time (E.g. 23:57-23:56) represents all-day
forbidden. End-time larger than start-time (E.g. 00:00- 23:59) takes
effective in this range.
Effective time period for user to unlock: all-day open (00:00-23:59)
or end-time larger than start-time in time period.
Note: System defaults that time period of serial number 1 is
all-day open, the new register user belong to the group1 and
own the serial number1 time period, so the new registered
user default can unlock door).