5. It is highly recommended that a set of safety infra-red beams be used in conjuncon with this product. The safety beams must be
installed in such a way that the product is prevented from running when anything is in the path of the door or gate.
6. Over and above the recommendaon to use safety infra-red beams with this product it is mandatory to install and use a safety
beam set when using the automac closing feature. It is recommended that a warning light be ed to any automaon system.
7. The gate or door warning labels must be installed in a prominent place and/or adjacent to any xed controls that trigger the
system. These must be in clear line of sight of the gate or door opening.
8. The emergency manual release instrucon label must be installed on or adjacent to the emergency manual release mechanism.
Aer installaon - It is the responsibility of the installer to ensure the users:
1. Is procient in the use of the manual emergency release mechanism.
2. Is issued with the documentaon accompanying this product.
3. Understands that the gate or door may not be operated out of clear sight.
4. Ensures that children are kept clear of the gate or door area at all mes, and that children do not play with the remote transmiers
or any xed trigger switches linked to the system.
5. Is instructed not to aempt to repair or adjust the automaon system and to be aware of the danger of connuing to use the
automaon system in an unsafe condion before a service provider aends to it.
6. Is procient in tesng the unit’s safety obstrucon sensing system.
7. Is aware of what to check for with regards to wear and tear that may need to be aended to from me to me by the service
provider.
8. Is aware that a fagued baery may not be disposed of in the general refuse and must be handed in at a baery merchant for safe
disposal. Before removing the baery from the system the household mains must be disconnected. In the case of the motor unit
being removed and scrapped, the baery must be removed rst.
TECHNICAL SPECIFICATIONS
Technical Data
Low trac opon
Plug in transformer (Not included in kit)
High trac ACDC
Standard kit
Rated gate mass. 1000kg 1000kg
Maximum gate travel. 40m 40m
Primary power supply to gate. 29Vac @ 1A 50Hz – 60Hz 220 – 240Vac @ 50Hz – 60Hz
Peak power consumpon at gate. 30W 350W
Electrical class. Class 3 Class 1
Motor voltage. 24Vdc 24Vdc
Motor current. Current limited to 13A. Current limited to 13A.
Duty cycle maximum.
See determining your duty cycle on PG (7)
25% with 220Vac present 98% with 220Vac present
Number of operaons on baery reserve.
(Baery health and charge level at me of
power failure dependent. Calcuted on a 5m
gate with rolling resistance of <15kgf)
100 using the standard 5Ah baery.
This can be upgraded to 150 by installing 2 x
3.5Ah baeries.
100 using the standard 5Ah baery.
This can be upgraded to 150 by installing 2 x
3.5Ah baeries.
Gate speed
At rolling resistance of <15kgf
Up to 28m/min. Can be adjusted down. Up to 28m/min. Can be adjusted down.
Rated Load 600N 600N
Operang temperature range -10 to 50° C (14F to 122F) -10 to 50° C (14F to 122F)
An-crushing safety sensing Yes – Electronic gate proling Yes – Electronic gate proling
Auxiliary supply output 12Vdc @ 400mA 12Vdc @ 400mA
Built in baery charger. Mulple stage auto-calibrang 500mA Mulple stage auto-calibrang 500mA
Receiver format
ET BLU MIX © backward compable with ET
BLUE (Rolling code)
ET BLU MIX © backward compable with ET
BLUE (Rolling code)
Receiver frequency 433.92MHz 433.92MHz
Receiver channels 4CH (BT, PED, Aux relay, Holiday lock-out) 4CH (BT, PED, Aux relay, Holiday lock-out)
Receiver memory capacity 1023 users 1023 users
All users can be allowed control of all channels Yes Yes
Ingress protecon IPX4 IPX4
Physical dimensions See next page. See next page.
Technical specicaons.