Et DRIVE 1000 - Magnetic Lock Mode

Et DRIVE 1000
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
41
Basic operang
features
Auxiliary relay modes.
Magnec lock mode.
User manual reference -
Page 16
With Magnec lock mode selected, the auxiliary relay will acvate half a second before the gate opens and remain acvive unl half a second aer
the gate has closed again.
Whenever a lock is installed with the system, a separate baery backed up power supply matching the lock load must be installed. Failure to do this
can damage the charger and baery of the control unit.
Below is an example of magnec lock mode when standard BT mode is acve.
Acon Response
Momentary BT trigger.
Auxiliary relay
acvates.
No buzzer tone.
Half a second aer
the auxiliary relay has
acvated.
Gate begins
opening.
No buzzer tone.
Gate reaches open
posion.
Gate stops. No buzzer tone.
Momentary BT trigger.
Gate begins
closing.
No buzzer tone.
At full closed posion. Gate stops. No buzzer tone.
Half a second aer gate
has reached the full
closed posion.
Auxiliary relay
deacvates.
No buzzer tone.
ON
Com N/O
N/C
OFF
Com N/O
N/C
0
0.5 sec.
0
0.5 sec.
Gate closed.