52
Displayed on screen. Denion. Soluon.
Master clr Reset Processor reset due to a hardware reset. If persistent, bring control card in for repair.
Motor Unwind
Motor backing o slightly aer overload to prevent gear system
jamming up.
Remove physical obstrucon.
No hi cur source No current source present to run the motors. Ensure either a baery or the PSU is connected.
None No log item recorded yet. A log will automacally build as the system is used.
Open half Gate is open halfway in “BT” Standard mode. Page 33.
Open PED Gate is open to the PED distance. Pages 37 and 38.
Open Run Ovload
A current overload occurred during the full speed poron of
travel while the gate was opening.
Remove physical obstrucon.
Open Slo Ovload
A current overload occurred during the crawl poron of travel
while the gate was opening.
Remove physical obstrucon.
Open Stall(enc)
The gate stalled (encoder counng no longer detected) while
opening.
Remove physical obstrucon.
Over temperature The board experienced an over temperature situaon. This will clear when temperature returns to normal.
Overload Gate has overloaded.
There could be an obstrucon in the path of the gate,
try increasing “Overload Seng”
Ped auto-close
disabled
If beams are disabled Ped auto-close will also be disabled, This
is an IEC standard.
Install a set of beams to facilitate any auto-close
funcon. Pages 15 and 19.
Ped auto-close
enabled = 2s
If beams are enabled Ped auto-close is enabled by default for
added security.
Page 38.
Ped length reset
to gate length
If the gate length is changed to be shorter than the PED length
then PED length is shortened.
Pages 18 and 21.
PED Mode Seng
< | 00mm >
Displays whether PED mode is in Auto-close or standard mode
and what the distance is set to.
Pages 37 and 38.
Pedestrian open
distance: 00mm
The distance the gate will open on a pedestrian trigger. Page 21.
Power error
braking
Device is about to shut down due to low power, motor is slowing
down.
Low AC, PSU and Bat voltages.
Power error
reseng
Device is about to shut down due to low power, processor is
waing to reset.
Low AC, PSU and Bat voltages.
Power on Reset Processor reset due to being powered up. Wait for display to show “Standby” before connuing.
Program Run-me
Gate run me has not been programmed before trying to run
gate.
Page 18.
PSU voltage high The PSU supply voltage is out of specicaon - too high. Check mains input is < 255Vac.
QC test passed Quality Control test was passed. Connue to use system as per normal.
Ramp Open Stall The gate stalled while ramping up in the open direcon. Remove physical obstrucon.
Remote not
Learnt
Learning error.
Check that you are using a matching frequency ET
Blue or ET BLU MIX transmier that is funconal.
Restore sengs Backed up sengs were restored. Page 30.
Run-me NOT set
Please perform a runme setup before aempng to run the
gate.
Page 18.
Searching Limit Gate is closing looking for the closed limit. Allow gate to connue all the way closed.
Set Limit before
Ped distance
The PED distance can not be set before the runme setup has
been completed.
Page 18.
Signal:
Not recognised
Unknown ET Blue or BluMix TX detected.
Program the remote buon into the receiver memory.
Page 22.
Soware Reset Processor reset due to a soware command. Connue scrolling through log.
Standby Motor in standby, everything operang normally. Connue to use the system as normal.
TRAP Reset Processor reset due to a soware error. If persistent, bring control card in for repair.
TX already in
memory
Remote already in memory, buon learnt but at a dierent
address.
Each remote can only occupy 1 memory address.
WARNING:
Bat Health: Poor
Warning if the baery health is poor and the gate is running o
baery.
Consider replacing the baery.
Watchdog Reset Processor reset due to a soware error. If persistent, bring control card in for repair.