25
071873-15-07/15 (translation of the original operating instructions)
Operating Instructions
Non-Contact Safety System CES-A-ABA-01/CES-A-ABA-01B
11.4. Read head CES-A-LCA-…
Ì Cube-shaped design 42x25mm
Ì PE-HD plastic housing material, suitable for use in aggressive media (e.g.acids, alkalis)
Dimension drawing
32
42
48
25
31
l
12
14
4,6
∅ 8
∅ 4,5
± 0,1
Active face
Active face
2 safety screws M4X14
included
Flat seal
NOTICE
The at seal provided must be used during assembly.
Typical operating distance
With evaluation unit CES-A-ABA-01 and actuator CES-A-BCA
-8
-4
-6
-2
2
6
4
8
0
2
4
6
8
Centre offset m [mm]
Distance s [mm]
OFF
ON
Actuator
Read head
s
m
Hysteresis
Switch-on
distance
ON
OFF
Hysteresis
Distance sS
ao
Output stage
Switch-off
distance
OFF
With evaluation unit CES-A-ABA-01B and actuator CES-A-BCA
Side
lobe
N
-10-15 -5 0
Centre offset m [mm]
Distance s [mm]
OFF
ON
Switch-on
distance
ON
OFF
Hysteresis
Distance sS
ao
Output state
Switch-off
distance
OFF
Hysteresis
-20 5 201510
5
10
15
20
Side
lobe
N
Actuator
Read head
s
m
NOTICE
For a side approach direction for the actuator and read head, a minimum distance of s=3mm must
be maintained so that the operating distance of the side lobes is not entered.
Approvals