Operating Instructions
Non-Contact Safety System CES-A-ABA-01/CES-A-ABA-01B
6
(translation of the original operating instructions) 071873-15-07/15
Table 1: Possible combinations for CES components
Evaluation unit Read head
Actuator
CES-A-BBA
071840
CES-A-BCA
088786
CES-A-BDA
084720
CES-A-BMB
077791
CES-A-BQA
098108
CES-A-NBA-...
All items
CES-A-BPA
098775
CEM-A-BE05
094805
CEM-A-BH10
095175
CET-A-BWK-50X
096327
CES-A-ABA-01
071850
CES-A-LNA...
All items
CES-A-LNA-SC
077715
CES-A-LCA...
All items
CES-A-LMN-SC
077790
CES-A-LQA-SC
095650
CES-A-ABA-01B
083513
CES-A-LNA...
All items
CES-A-LNA-SC
077715
CES-A-LCA...
All items
CES-A-LMN-SC
077790
CES-A-LQA-SC
095650
CEM-A-LE05K-S2
094800
CEM-A-LE05R-S2
095792
CEM-A-LH10K-S3
095170
CEM-A-LH10R-S3
095793
CET-AX
Key to symbols
Combination possible
Combination possible, guard locking for process protection
Combination possible, guard locking for personal protection
Combination not permissible
3. Description of the safety function
Devices from this series feature the following safety functions:
The following applies in combination with read heads without guard locking (CES read heads) and read heads with guard
locking for process protection (CEM/CET read heads):
Monitoring of the position of a safety guard (interlocking device according to EN ISO 14119)
Ì Safety function:
- The safety contacts are switched off when the safety guard is open (see chapter 11. Technical Data on page 18).
Ì Safety characteristics: Category, Performance Level, PFH
d
(see Technical data CES‑A‑ABA‑01B on page 19).