Technical data
Parameter Value Unit
min. typ. max.
Housing material Fortron, reinforced thermoplastic, fully encapsulated
Dimensions 50x50x20.2 mm
Weight 0.08 kg
Ambient temperature -25 - +70 °C
Degree of protection IP67
Installation position Any
Method of operation Inductive
Power supply Via evaluation unit
In combination with actuator CES-A-BBA or CES-A-BCA
Assured switch-off distance S
ar
- - 47
mm
Operating distance for center offset m=0
1)
- Switch-on distance - 15 -
- Assured switch-on distance S
ao
10 - -
- Switching hysteresis 2 3 -
In combination with actuator CES-A-BQA on evaluation unit CES-A-ABA-01B
Assured switch-off distance S
ar
- - 60
mm
Operating distance with vertical approach direction
Center offset m=0
1)
- Switch-on distance - 23 -
- Assured switch-on distance S
ao
16 - -
- Switching hysteresis 2 3 -
Operating distance with side approach direction
Distance in x direction=10mm
- Switch-on distance - 28 -
- Assured switch-on distance S
ao
24 - -
- Switching hysteresis 1 1.3 -
Connection cable
- - 25 m
1) These values apply to surface installation of the read head and the actuator.