EasyManuals Logo

EUCHNER TP Series User Manual

EUCHNER TP Series
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
9
Operating Instructions
Safety Switch TP…
Figure 2: Dimension drawing for TP…
Necessary minimum travel + permissible overtravel
Approach direction Standard actuator Overtravel actuator
Horizontal (h) 28 + 2 28 + 7
Vertical (v) 29.5 + 1.5
Only on
TP…K…
29.5 + 7
With escape release (short/long actuator shaft)
61,5
74,7
67,5
53
36
4
14
20
31
M4
Always install the escape
release lever on the
recessed side
Establish a positive
connection between the
shaft and lever.
Key to symbols
/
Guard locking ready for operation
/
Guard locking released
76,5
20,5
19
39
Direction of rotation
Marking
With auxiliary key release
Lock function
Type Lock Key removable in position
TP…C1844
Identical locking
and
With plug connector SR6/SR11
Locking screw
Auxiliary release
Auxiliary release with triangu-
lar wedge
(two triangular keys included)
For M5 > 35 mm
ISO 1207 (DIN84)
ISO 4762 (DIN912)
M = 1.5 Nm
M = 0.8 Nm
green
red
LED module en-
closed separately.
Observe assembly
instructions.
M = 0.8 Nm
Type TP…K…
35
3,5
30
40
144
192
31
22
16
42
16
43
8,5
3,5
h
28
42
3,5
199
50
h
v
v
M20x1.5 / PG13.5 / NPT½" (3x)
4,
8
50
76,5
39
615
<35>
33
With wire front release
Actuating head with insertion funnel
h
31
3,5
196
35
47
v
0,3
Type TP…K… is not suitable for
operation with a bolt.
Short actuator shaft
Long actuator shaft

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EUCHNER TP Series and is the answer not in the manual?

EUCHNER TP Series Specifications

General IconGeneral
BrandEUCHNER
ModelTP Series
CategorySwitch
LanguageEnglish

Related product manuals