EasyManua.ls Logo

Evco EVJ805P9VX3 User Manual

Evco EVJ805P9VX3
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
EVCO S.p.A. EVJ800 | Installer manual ver. 1.0 | Code 144J800E104
page 1 of 48
EVJ 800 series
Controllers for blast chillers
ENGLISH
INSTALLER MANUAL ver. 1.0
CODE 144J800E104
Question and Answer IconNeed help?

Do you have a question about the Evco EVJ805P9VX3 and is the answer not in the manual?

Evco EVJ805P9VX3 Specifications

General IconGeneral
BrandEvco
ModelEVJ805P9VX3
CategoryController
LanguageEnglish

Summary

2 INSTALLATION

2.2 Measurements and installation

Provides detailed measurements and panel mounting instructions for front and rear installation.

Installation precautions

Lists essential precautions for safe and proper installation, covering environmental and physical placement.

2.3 Electrical connection

Illustrates the wiring diagrams for connecting the EVJ805 and EVJ815 models.

4 DISPLAY

5 SETTINGS

5.4 Parameters

Details how to access and modify device parameters, including password entry.

6 FUNCTIONS

6.3 Blast chilling/blast freezing and conservation

Details how to select and start blast chilling/freezing cycles and switch between modes.

7 MANAGING THE LOADS

7.2 Compressor

Details the compressor management logic for various cycles like chilling, freezing, defrosting, and thawing.

7.3 Evaporator fans

Explains the management of evaporator fans during different cycles and probe presence.

7.4 Condenser fans

Details the management of condenser fans based on probe presence and compressor status.

8 CONFIGURATION PARAMETERS

MAIN REGULATOR

Details parameters for cabinet setpoint differentials, durations, and product temperatures.

COMPRESSOR PROTECTION

Details parameters for compressor protection, including minimum times and probe error handling.

DEFROST

Lists parameters governing defrost intervals, types, duration, and start-up.

TEMPERATURE ALARMS

Details parameters for minimum and maximum temperature alarms, including delays and enable settings.

EVAPORATOR AND CONDENSER FANS

Lists parameters controlling evaporator and condenser fan operation during various cycles.

9 ALARMS

9.1 Alarms

Explains how alarms are displayed and lists various alarm codes, causes, and main results.

10 TECHNICAL SPECIFICATIONS

10.1 Technical specifications

Provides a comprehensive list of the device's technical specifications.