EVCO S.p.A. EVJ800 | Installer manual ver. 1.0 | Code 144J800E104
page 31 of 48
r20 -20 -50 99 °C
Product temperature setpoint for the first phase of sanitation
and cabinet temperature setpoint for the second phase of
sanitation
r21 24 0 24 h Duration of second sanitation phase
r22 -20 -50 99 °C Cabinet temperature setpoint for the third phase of sanitation
r23 5 1 99 h Maximum duration of the first sanitation phase
r24 10 1 400 min Duration of ice cream hardening cycle
r25 25 -50 99 °C Initial cabinet temperature setpoint for light-load thawing
r26 30 -50 99 °C Initial cabinet temperature setpoint for medium-load thawing
r27 35 -50 99 °C Initial cabinet temperature setpoint for heavy-load thawing
r28 10 -50 99 °C Final cabinet temperature setpoint for light-load thawing
r29 12 -50 99 °C Final cabinet temperature setpoint for medium-load thawing
r30 15 -50 99 °C Final cabinet temperature setpoint for heavy-load thawing
r31 3 -50 99 °C Cabinet temperature setpoint for post-thawing conservation
r32 240 1 999 min Light-load thawing duration
r33 480 1 999 min Medium-load thawing duration
r34 720 1 999 min Heavy-load thawing duration
r35 0 1 1 - - - -
Value that can be set in quick mode during the cycle selection
phase before starting the cycle itself
0 = working setpoint during the cycle (or cycle final phase
setpoint for 2-phase cycles)
1 = end-of-cycle needle temperature (for temperature
controlled cycles) or cycle duration (for time controlled
cycles)
r36 0 1 1 - - - -
Storing the set value in quick mode during the cycle selection
phase
0 = no: at the start of the next cycle the default values of
the parameters will be re-offered
1 = yes: at the start of the next cycle the values last used by
the same cycle type will be repeated
r37 80 -50 99 °C Maximum cabinet temperature setpoint that can be set
PAR. DEFAULT
MIN. MAX. U.M. HEATING REGULATOR
r38 1 0 10 °C Neutral zone relative threshold for thawing
r39 2 1 15 °C Cabinet setpoint differential for activating heater during thawing
r40 2 1 15 °C
Cabinet setpoint differential for activating compressor during
thawing
r41 45 1 600 s Heater cycle time for thawing
r42 4 1 600 s Heater on time for thawing