Even-GLO™ Series GA301
Page 38
October-28-15
Lighting Instructions for Models GA301-M & GA301-MP
Caution:
Heater will produce smoke the first time it is lit. This is normal. Make sure NOT to light
the heater in an enclosed area.
Lighting Instructions for Models GA301-U, GA301-T, & GA301-H
1. Open manual gas supply valve (ensure gas supply lines have been purged).
2. Turn on switch to energize electric supply.
3. The electronic control module will time begin the ignition period in 3 seconds.
4. The gas valve will open and ignition spark will commence and continue for 20 sec.
5. If flame starts and “is detected”, flame will continue until turned off.
6. If no flame is detected, the gas valve will close after 20 sec. A “wait’ period
commences and lasts approximately 5 sec. and a second trial for combustion
commences. The electronic control will attempt three trials for ignition before
locking out for approximately 5 minutes at which time it will automatically try again.
Electronic control of heater can be re-set by de-energizing and re-energizing electric
power.
Lighting & Shutdown Instructions