EasyManua.ls Logo

evertz 3067VIP-3G-36x4 - User Manual

Default Icon
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
3067VIP-3G-36x4
Next Generation Quad Outputs, Compact Multi-Image
Display Processors
User Manual
© Copyright 2020
EVERTZ MICROSYSTEMS LTD.
5292 John Lucas Drive
Burlington, Ontario
Canada L7L 5Z9
Phone: +1 905-335-3700
Sales: sales@evertz.com Fax: +1 905-335-3573
Tech Support: service@evertz.com Fax: +1 905-335-7571
Web Page:
http://www.evertz.com
Version 1.0, February 2020
The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of
purchasers of the 3067VIP-3G series product. Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the
operation of the 3067VIP-3G series product. Due to on going research and development, features and specifications in this manual are subject to
change without notice.
All rights reserved. No part of this publication may be reproduced without the express written permission of Evertz Microsystems Ltd. Copies of
this manual can be ordered from your Evertz dealer or from Evertz Microsystems.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the evertz 3067VIP-3G-36x4 and is the answer not in the manual?

Summary

IMPORTANT SAFETY INSTRUCTIONS

USER INFORMATION AND COMPLIANCE

European Union Compliance

Details compliance with European Union EMC directive for Class A devices.

USA FCC Compliance

Details compliance with FCC Rules Part 15 for Class A devices.

OVERVIEW

Product Features and Benefits

Lists key features and benefits of the 3067VIP-3G-36x4 display processor.

TECHNICAL SPECIFICATIONS

Serial, Video, and Connectivity Specs

Details serial video inputs/outputs, display output, genlock, and Ethernet specs.

Electrical and Monitoring Specs

Covers electrical characteristics and available monitoring options.

GETTING STARTED

Rear Panel and Hardware Installation

Describes the rear panel and provides hardware installation steps.

Initial Network Configuration

Instructions for initial network configuration setup.

WEB INTERFACE

WebEASY Login and System Tab Overview

Accessing the WebEASY® interface and exploring the System tab.

SYSTEM TAB CONFIGURATION

Control Port, Reference, and Temperature

Configure control ports, monitor reference, and check temperature.

License Control and Product Features

Manage product licenses and view enabled features.

Trap, Security, and Time Controls

Configure trap, security, and global time settings.

SYSTEM TIME MANAGEMENT

Time Source and Zone Configuration

Configure time source (Local/NTP) and select time zones.

INPUT PROPERTIES CONTROL

Input Settings and Video Properties

Configure input settings, video standards, and GPI triggers.

Input Audio Properties

Configure audio properties like level bar type and Dolby E settings.

INPUT MONITOR

Input Monitor Details

Monitor input name, video standard, and CRC errors.

Input Video Monitor

Monitor video standard, aspect ratio, and VITC data.

OUTPUT CONTROL

Output Resolution and Layout

Configure output resolution, layout, and rotation settings.

Output Refresh Rate and Audio

Set output refresh rate and configure audio output.

UMD CONTROL

UMD Proxy Control Configuration

Configure UMD protocol and port settings for readers.

SYSTEM NOTIFY

Global and Temperature Notifications

Configure system, temperature, and link status notifications.

VIDEO NOTIFY

Video Monitoring and Notification Settings

Configure video monitoring thresholds and notification traps.

AUDIO NOTIFY

Audio Monitoring Control (Part 1)

Configure audio over and silence level and duration settings.

Audio Monitoring Control (Part 2)

Configure mono detection and phase reverse settings.

ADVANCED NOTIFY CONTROL

Picture Level Control

Configure advanced picture level fault detection thresholds.

CC and TXT Control

Configure Closed Caption and Teletext loss detection.

Nielsen and EIA 708 Control

Configure Nielsen and EIA 708 caption loss detection.

ANC and Video Control

Configure Ancillary Data and video fault detection.

ADVANCED NOTIFY

Advanced Video Traps and Faults

Configure advanced video fault monitoring and trap settings.

ADVANCED AUDIO NOTIFY

Non-PCM Audio Controls

Configure Non-PCM audio loss and change detection.

Audio Loudness Monitoring

Configure and monitor audio loudness levels.

AUDIO LOUDNESS NOTIFY

Audio Loudness Fault Configuration

Configure audio loudness traps and fault indicators.

THUMBNAIL CONTROL

Thumbnail Server and Input Properties

Configure thumbnail server settings and input properties.

ADVANCED INPUT NOTIFY

Advanced Input Traps and Faults

Configure advanced input fault monitoring and trap settings.

Timecode GPI and SCTE 104 Controls

Configure Timecode GPI and SCTE 104 duration reset settings.

GPIO CONTROL

GPIO Control Configuration

Configure GPIO IP address and port number.

FIRMWARE UPGRADE

WebEASY Firmware Upgrade Procedure

Procedure for upgrading firmware via the WebEASY® interface.

evertz 3067VIP-3G-36x4 Specifications

General IconGeneral
Model3067VIP-3G-36x4
Frame SynchronizationYes
Inputs36
Outputs4
Standards SupportedSMPTE 259M, 292M, 424M
Audio ProcessingEmbedded audio
Control InterfaceEthernet
Video Standards3G-SDI, HD-SDI, SD-SDI
Power SupplyRedundant Power Supplies