01-2018 5035 01 65
SYSTEM
compoNENt tEst
Allows the appliance’s main components to
be checked.
The components that can be checked are
displayed.
Choose the component to be checked.
brEwiNg uNit
Starts moving the brewing unit.
EsprEsso coNtaiNEr
A dose of coee beans is ground.
motor-DosEr
The instant powder motor-doser is activat-
ed for a few seconds.
mixEr
The mixer is activated for a few seconds.
ligHtiNg
The appliance’s lighting is activated for a
few seconds.
solENoiD valvEs
The selected solenoid valve is activated for
a few seconds.
pumps
The selected pump is activated for a few
seconds.
During the test, hot water is dis-
dispensing area.
sENsor aND iNput DEvicE tEsts
Displays the status of the appliance’s vari-
ous sensors and/or controls (probes, micro-
switches, etc.)
For devices with ON/OFF functions, the
status is shown using colour: green is used
if the appliance is active/ actuated, and red
is used is it is disabled/ not been actuated.
For the sensors, the detected value is dis-
played (e.g. temperature).
output DEvicE tEsts
Allows the operation of the appliance's vari-
ous components to be checked.
The components that can be checked are
displayed.
Choose the component to be tested.
For safety reasons the tests must be
carried out with the door closed.
Press and hold down the component button
to activate it and to check that it is working.
When the button is released, the compo-
nent will be turned o.
toucHscrEEN tEst
Allows the touchscreen function to be
checked.
Tap and drag your nger across the touch-
screen.
Each tap leaves a dierent-coloured trace.