EasyManua.ls Logo

Evolights SPARK PRO - General Troubleshooting

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
Spark Seed would easily get damp in the open air and deliver poor spark effect. Storing
damp Spark Seed in the machine storage bin will do harm to machine and cause clog-
ging. Please empty the storage bin after each use.
9.2.2. Spark seed storage & recycling
9.2.2.1. Sealed spark seed storage
Spark Seed should be stored in a cool, dry place, vacuum packed in foil bags, and protected from
moisture, heat, hot surface, open fire and other ignition sources.
9.2.2.2. Spark seed recycling
Store the unfinished Spark Seed in the Recycling Tube with the Funnel. Keep it sealed and away from
moisture.
9.3. General troubleshooting
9.3.1. Device error description
When error happens, device will stop working and heating system shuts off automatically. LCD
shows corresponding error code.
9.3.2. Device error menu map
Errors
Display
Possible cause
Over
heat shutdown
Device Error
E0
The heating system temperature is higher
than 700 over 30 seconds.
Heating up failed
Device Error
E1
Heating system cannot reach pre-set target
temperature after 10-min heat-up.