Once you have your Eazy ready to be cleaned as described in the previous
section you are ready to clean your Eazy as explained below.
Open the top air valve to the Eazy then close the bottom valve to the outer 1.
chamber as shown in Fig 13. The Kaldnes in the “Eazy” shall start to aerate
within a few minutes as shown in Fig 14.
After the “Eazy” has been aerating for a minimum of three minutes, open the 2.
1.5” (50mm) waste valve (G) to drain waste from the inner Nexus chamber.
Once the central chamber has drained it is recommended you give a quick 3.
clean to the inner chamber and outer stainless steel of the Eazy with a hose
then close the 1.5” waste valve.
Gravity Fed - Remove inlet slide-plate (Gravity Fed) until level stabilises then 4.
replace slide plate.
Pump Fed - Open single union ball valve and start pump allowing inner 5.
chamber to rell until the water cleaning level is reached as in Fig 14. Then
close valve and switch of pump.
The Eazy should now be aerating again. After the Eazy has boiled for another 6.
few minutes open the waste valve again.
Repeat steps 1-6 until the water after aerating is fairly clean7.
Close the airvalve to the Eazy and re-open the valve to the outer chamber8.
Go back to previous instruction for pump or gravity fed.9.
CLEANING THE EAZY
-10-
Figures 12-14
Starting Clockwise
from Above