IONPURE
®
LX CEDI Modules
Page 8 IP-MAN-LX-1220-EN.pdf
1.2. Using This Manual
Service technicians should review this manual prior to going to the installation site. It lists
tools and materials needed to install the modules. It also outlines the site information
required to prepare for installation.
NOTE: The warranty may be void if installation or operation instructions contained in this
manual are not followed exactly.
This manual describes the installation, operation, and routine maintenance of the LX
modules. It also contains information on basic troubleshooting (See Section 7).
IONPURE strongly recommends all users read the entire contents of the manual. If the
LX module is not operating properly after going through the basic troubleshooting
exercises, contact your Local Service Provider.
1.3. Installation Precautions
· During operation, the electrode wiring inside the module junction
boxes are at high voltage and present a shock hazard.
THEREFORE, BEFORE TOUCHING THE INSIDE OF THE
JUNCTION BOX, CONFIRM THAT AC POWER TO THE DC
POWER SUPPLY HAS FIRST BEEN DISCONNECTED AND
LOCKED OUT ACCORDING TO STANDARD LOCKOUT/
TAGOUT PROCEDURES.
· To minimize the possibility of electric shock, confirm that all ground
wires are properly connected.
· Do not open the LX module. Opening the module will void the
warranty and cause irreversible damage.
· The module must be operated according to the design
specifications for temperature and humidity.
· Metal piping should never be connected directly to the module.
Non-metallic piping adapters are required at the module inlets and
outlets. It is then allowable to transition to metallic piping.
· Pipe sections prepared for installation must be inspected, and be
free of debris from storage or cutting tool particles. This must be
done before installation.
· Because LX modules have narrow flow distribution channels,
plugging by particles can cause permanent damage. Always
install pressure gauges, sampling ports, sensors, etc. in tee
fittings. Do not drill or tap into piping.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Evoqua IONPURE IP-LXM04 and is the answer not in the manual?

Evoqua IONPURE IP-LXM04 Specifications

General IconGeneral
BrandEvoqua
ModelIONPURE IP-LXM04
CategoryControl Unit
LanguageEnglish

Related product manuals