setting
temperature
Function
Setting
Range
temperature
difference
Operating
cycle
Defrost time
Delay time
LS+1HS- 1
1,015,0
199
145
5,035,0
15
General settings:
Exit
temperature
1 : AC220V ±10 50HZ/60HZ
2 : 5A/220V/AC
3 3W
4 : 1050 R H90%
5 :- 0.050.0
6 1.0 ±1.0
7Input signal:
× ×
×
Operating voltage
Output Load
Power Consumption
Working environment
Control Range 5
Resolving Power Accuracy
Overall Dimension 120(length) 53(wide) 84(high)mm
Starter Size: 92(length) 44(wide)mm
8Evaporator fan operation mode: fan is provided with
normally open, start / stop, delay (1 ~ 5 minutes
adjustable) operation.
9Defrost mode: electric or steam defrosting.
10Manual / automatic defrosting: forced entry and exit
defrosting, defrosting exit time and temperature of
double insurance.
11
12
two-way storage temperature sensor,
10Kx1.5mx2
286A-2016.08.16
Microcomputer Thermostat Serial
EW-286 Directions
Welcome to choose our instruments. This product
is a specialize micro-computer temperature
controller for refrigerator and freezer. The panel in
English takes it easy to use and avoid entering
confusing menu represents the parameter setting.
Our sensor is precisely ma-de and sealed. It is
moisture proof, therefore its performances are more
stable and reliable.
Ex-factory
Value
Hour
Unit
Notes.
Temperature
correction
-15,015,0
-10,0
3,0
6
10
3
5,0
0,0
Mins
Mins
When reaching the set
temperature, the compressor
control switch OFF
Heating to the set temperature + return
difference, compressor control
switch connected
Interval between two
defrosting
Working time of
deforsting
Delay time before staredt
Defrosting ending
temperature
Hold an d 6nds
to set this value
Advanced Settings:
Code
Function
Upper limit
Lower limit
Dripping
time
Defrost
mode
Evaporator
Fan Mode
Setting Range
-50 to temp control -1
Temp control +1 to 50
-15
010
01
Ex-factory
Value
50,0
-50,0
01
2
0
Unit
Mins
Notes.
Exceeds a set value
alarm
Exceeds a set value
alarm
Parameters: when “-1”
the fan normally open;
when “0, the fan and
compressor start with
the same stop, compressor
start delay after 1-5
minutes.
Each delay time after
defrosting, and “0” for
no dripping time
When set to “0” is
electric defrosting
When set to “1” is
steam defrosting
220V/AC
Mode: EW-286A
220V/AC
E
vapora
to
r
fan
Def
ro
s
t
Storehouse
sensor
Defrost
sensor
Output Load:
5A/220V/AC
1
2
3
4
5
6
7
8
9
0
1
1
1
1
1
1
1
2
3
4 5
5A 5A 5A 5A
A
l
a
r
m
C
o
m
pr
e
s
so
r
Technical Specifications
Appearance Panel
heat
temp
heat
time
up
set
down
Evaporator
Thermal insulating material
Defrosting sensor
Low-voltage air-return pipe
The sensor is installed the distance 5-10cm.
Wiring diagram
Parameters for Procedure