1Operating VoltageAC220V ±10% 50HZ/60HZ
2Load Current10A/220V/AC
3Power Consumpion3W
4Working Environment1050 RH 90%
5Control Range:-7 04 0 0℃/-7 08 0 0
6Resolving1 accuracy±3
7Input Signal: One way PT100 ( equipped by user )
8Outputone-way contro
9Overall Dimension78(length)×35(wide)×62(high)mm
1 0Starter71(length)×29(wide)mm
Temperature difference
Setting range: 1 ° C ~ 15 ° C or
1°F60°F
High temperature alarm.
Setting range: (control temperature + d + 1) ° C ~ 415 ° C
Or (control temperature +d+1) °F ~ 800 °F
Temperature correction.
Setting range: -25 ° C ~ 25 ° C or
-60 ° F ~ 60 ° F
Delayed start.
Setting range: 0 to 3 minutes
EW-986GP Directions
Microcomputer Thermostat Serial
Firstly thanks for using our instrument. This product is
a new product of fully automatic intelligent control sy-
stem especially made for high-temperature and heating
industry.
1.The voltage must accord with controller's demand. The
voltage's deviation is no more than ±10%.
2.The loop of sensor is possible to keep away from the
loop of power.
3.The sequence of line's must have been connected
Properly.
:986GP.18.09.06
When the current temperature and the
temperature value is rotated displayed.
> .
When it is
cooling state, it enters the fault running state.
(ON for 45 minutes, OFF for 15 minutes); When
the state of heating relay OFF.
When the current temperature < , and the
temperature value is rotated displayed. When it is
heating state, continue heating; If cooling state
the relay d .isconnect
S
e
t
PV
SV
C
Heating System Indicator
Fault Indicator
Current Temperature
Setting
indicator
S
e
t
SV
S
e
t
SV
S
e
t
SV
S
e
t
SV
S
e
t
SV
S
e
t
PV
S
e
t
PV
Temperature conversion:
C is displayed in Celsius temperature,
F is Fahrenheit temperature display
S
e
t
PV
S
e
t
SV
Cooling System Indicator
Cooling heating conversion. Under this menu,
press or first time to display the original
set value.Press again to modify the set value.
Setting range: H or C
Low temperature alarm.
Setting range: -75 °C ~ (control temperature - d-1) °C
Or -75 °F ~ (control temperature - d-1) °F
When the sensor line is open or shorted, an E1 alarm.
If the controller is in the cooling state, it enters the
fault operation state (ON for 45 minutes, OFF for 15
minutes); when it is heated, the relay is disconnected.
S
e
t
PV
3. Reset: Non-set state, press for 5 seconds, the display
flashes, all parameters are reset to factory settings
1 . ,SV light ON,
o r
The setting range is also limited by and . Please
see the parameter settings below for details.
Temperature setting: Press display con
trolling temperature, press to change controlling temp-
erature..
2 .
Parameter Setting: Press for 6 seconds to start parameter
setting, will be displayed. Press to adjust the parameters
of
Technical Specifications
Brief on Operation
Demand of install
Operating Procedure
Question and Answer IconNeed help?

Do you have a question about the EWELLY EW-986GP and is the answer not in the manual?

EWELLY EW-986GP Specifications

General IconGeneral
BrandEWELLY
ModelEW-986GP
CategoryThermostat
LanguageEnglish

Related product manuals