EasyManua.ls Logo

eXact Pool EZ - Product and Reagent Information; Reagents and Test Parameters

eXact Pool EZ
28 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
©2016, Industrial Test Systems, Inc. Printed in USA
Value provided represents best possible accuracy under laboratory conditions, but may vary throughout the detection
range.
For a complete list of accuracies throughout all ranges, please visit sensafe.com/photometers/pool-exact-ez/.
1
Performance veri ed with various salt systems and water samples with optimal water temperature at 10-40˚C / 50-104˚F.
Optimal water temperature for Phosphate test is 15-40˚C / 59-104˚F.
2
For detailed instructions on using this product, contact us (see below) or visit sensafe.com/photometers/pool-exact-ez/.
3
Requires the use of 2 strips if reading is above 6 ppm.
4
Combined Chlorine DPD-3 Test requires Free Chlorine DPD-1 (486637) to be run rst.
For resellers and distributors - products sold in case quantities (12 units per case).
PATENT INFORMATION
US Patent #7,333,194; Euro Pat No. 1 725 864 DE FR UK; South Africa Pat No 2007/0628
by Industrial Test Systems, Inc., 1875 Langston Street, Rock Hill, SC USA.
EXACT
®
is a registered trademark of Industrial Test Systems, Inc. Rock Hill, SC USA.
EXACT
®
MICRO TESTS & REAGENTS
PARAMETER / TEST
1
PART #
RANGE
ppm
% BEST
ACCURACY
# OF
TESTS
Alkalinity, Total 486641 10 – 200 10 100
Alkalinity, Total Range Extender
2
486665 Each strip adds 130 ppm 100
Chloride (Salt)
486757
80 – 6700 5 25
Chlorine, Free (DPD–1)
3
486637 0.01 – 12.0 5 100
Chlorine, Combined (DPD–3)
4
486638 0.01 – 12.0 5 100
Copper
486632
0.06 – 9 2 50
Cyanuric Acid
481652-II
3 – 110 12 60
Hardness, Calcium 486629 3 – 700 5 50
pH 486639-II 6.4 – 8.4 0.2 pH 100
Phosphate 486814 0.02 – 4 8 50
EXACT REFILL BOX
PART #
PARAMETER / TESTS
Pool Re ll Box 486211
Total Alkalinity, pH, Free Chlorine,
Combined Chlorine, Calcium
Hardness, Cyanuric Acid
R072016-PEZQG
Visit us online:
sensafe.com/photometers/pool-exact-ez/
for up–to–date product information.
SENSAFE ITSSENSAFE
Industrial Test Systems, Inc.
1875 Langston Street
Rock Hill, SC 29730
1–800–861–9712—Inside the U.S.A.
1–803–329–9712—Outside the U.S.A.
Fax:1–803–329–9743
Email: ITS@SENSAFE.COM
WWW.SENSAFE.COM
ITS EUROPE, LTD
The UK Centre for Homeland Security
Building 7, Chilmark
Salisbury, Wiltshire, SP3 5DU, UK
Phone: +44 (0)1722 717911
Fax: +44 (0) 1722 717941
Email: ITSEUROPE@SENSAFE.COM
WWW.ITSEUROPE.CO.UK
MANUFACTURED BY
Pool
ADVANCED PHOTOMETER SYSTEM