EXCELL PRECISION CO., LTD.
17
02029018
ZSME300000363
RS-232 Interface Format
I . Mode: UART Signal of EIA-RS0232 C
II . Format :
1. Baud rate : 1 200, 2 400, 4 800, 9 600 bits/second
2. Data bits : 8 bits
3. Parity bit : None
4. Stop bits : 1 bit
5. Code : ASCII (Exchange code of American standard)
Start bit Data bits Stop bit
RS-232 Data Format
Stable transmission (
), Continuous transmission (
),
Press key to transmit ( )
(1) gram as weight unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
g
HEAD , HEAD , ± DATA UNIT CR LF
(2) kg or lb as weight unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
kg/l
b
HEAD , HEAD , ± DATA UNIT CR LF
(3) lb.oz as weight unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Lb.oz
HEAD , HEAD , ± DATA UNIT CR LF
(4) HK tael as weight unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
HK
tael
HEAD , HEAD DATA UNIT CR LF
(5) viss as weight unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
viss
HEAD , HEAD , ± DATA UNIT CR LF