Expobar Markus MINI - Connection Types; Electrical Installation

Expobar Markus MINI
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
Markus
INSTALLATION
Electrical installation
Connection types
Connect the machine as per the instructions on the ratings plate.
Machine: Supply
220-240Vac Ph+N
NEUTRAL
PHASE
Supply cable
Blue
Brown
Yellow/Green
220-240Vac Ph+N
Machine: Supply
2Ph 220-240Vac
PHASE
PHASE
Supply cable
Blue
Brown
Yellow/Green
220-240Vac Ph+N
Machine: Supply
3Ph 220-240Vac
PHASE
Supply cable
Blue
Brown
Yellow/Green
220-240Vac 3Ph
Machine: Supply
220-240Vac Ph+N
NEUTRAL
PHASE
Supply cable
Blue
Brown
Yellow/Green
2Ph+N
Black
Machine: Supply
2Ph 380Vac+N
NEUTRAL
PHASE
Supply cable
Blue
Brown
Yellow/Green
2Ph+N
PHASE
Black
Machine: Supply
2Ph 220-240Vac
NEUTRAL
PHASE
Supply cable
Blue
Brown
Yellow/Green
2Ph+N
Black
Machine: Supply
3Ph 220-240Vac
PHASE
Supply cable
Blue
Brown
Yellow/Green
2Ph+N
Black
PHASE
PHASE
Machine: Supply
125Vac Ph+N
NEUTRAL
PHASE
Supply cable
Blue
Brown
Yellow/Green
125Vac Ph+N
Machine: Supply
3Ph 380Vac+N
NEUTRAL
PHASE
Supply cable
Blue
Brown
Yellow/Green
380Vac 3Ph
Grey
Black
PHASE
PHASE
Black
PHASE
PHASE
DANGER!
If the mains cable or plug is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid SERIOUS INJURY OR DEATH!
The machine should only be connected to the power supply by qualified
personnel. The following safety instructions should be obeyed at all times:
Ensure that the electrical requirements stated on the TECHNICAL
SPECIFICATIONS (pages 7 - 8) match the specifications of the power
supply at the outlet.
Ensure that the domestic electrical supply where the machine is being
installed is rated for and able to provide the power required by the
machine. Insufficient power supply, wiring, grounding, or insulation can result
in overheating and possibility of fire.
The coffee machine must be connected to an earth grounded electrical
outlet that complies with the regulations in force in the country of
installation.
Ensure that a circuit breaker engineered for the power consumption of the
machine is installed to protect the domestic electrical supply, as specified on
the ratings plate located under the drip tray.
Do not connect the machine to the domestic power supply via extension
cords, plug adapters, or shared outlets.
The manufacturer will not be held liable for damage to persons, animals or
property resulting from incorrect installation of the coffee machine.