MESSAGES AND ALARMS
Fault in flow meter X /
Flow fault detected in counter X
Flow meter
Gr. X
Check that the machine is receiving water.
Time-out alarm
Boiler filling up
Temperature sensor fault
Probe unconnect
Service the machine.
To disable the alarm and reset the counter:
Turn off the machine. Simultaneously press and hold the
1 Short Espresso and 1 Long Espresso
buttons. Turn on the machine.
Service
999999999
Regenerate the filter.
To disable the alarm and reset the counter:
Turn off the machine. Simultaneously press and hold the
2 Short Espressos and 2 Long Espressos buttons.
Turn on the machine.
Change filter
999999999
If boiler filling time exceeds the programmed time (2 minutes), all of the Drink buttons lights will
flash and the machine will be disabled. To re-enable it, turn the machine off and on again at the power
switch.
If the electronic control panel does not receive a pulse from the flow meter (i.e.: coffee grind is too fine
or flow meter fault) within 5 seconds of pressing one of the espresso buttons, the light for the dose
selected will start to flash. To disable it, press the dose button again.
As an additional safety, all dose settings have a maximum dispensing time of 5 minutes.