480403 V1.0 6/07 3
Inspect the test leads for damaged insulation or exposed
metal. Check test lead continuity. Damaged leads must be
replaced. Do not use the meter if it appears damaged.
Use care when working above 30V ac rms, 42V ac peak and
60V dc. Such voltages pose a shock hazard.
When using the probes, keep fingers away from probe
contacts. Keep fingers behind the finger guards on the
probes.
Measurements can be adversely affected by impedances of
additional operating circuits connected in parallel or by
transient currents.
Verify operation prior to measuring hazardous voltages
(voltages above 30V ac rms, 42V ac peak and 60V dc).
Do not use the meter with any of the parts removed.
Do not use the meter near explosive gas, vapor, or dust.
Do not use the meter in a wet environment.
Warranty
EXTECH INSTRUMENTS CORPORATION warrants this instrument
to be free of defects in parts and workmanship for one year from date
of shipment (a six month limited warranty applies to sensors and
cables). If it should become necessary to return the instrument for
service during or beyond the warranty period, contact the Customer
Service Department at (781) 890-7440 ext. 210 for authorization or
visit our website www.extech.com for contact information. A Return
Authorization (RA) number must be issued before any product is
returned to Extech. The sender is responsible for shipping charges,
freight, insurance and proper packaging to prevent damage in transit.
This warranty does not apply to defects resulting from action of the
user such as misuse, improper wiring, operation outside of
specification, improper maintenance or repair, or unauthorized
modification. Extech specifically disclaims any implied warranties or
merchantability or fitness for a specific purpose and will not be liable
for any direct, indirect, incidental or consequential damages. Extech's
total liability is limited to repair or replacement of the product. The
warranty set forth above is inclusive and no other warranty, whether
written or oral, is expressed or implied.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extech Instruments 480403 and is the answer not in the manual?

Extech Instruments 480403 Specifications

Operating Environment IconOperating Environment
operating temperature32 to 104°F (0 to 40°C)
operating humidity15 to 85% relative humidity
operating altitude2000 m
Power IconPower
battery type9V battery
current consumption20 mA max
battery lifeOne year minimum
Electrical Specifications IconElectrical Specifications
nominal voltage120 to 400 VAC
frequency range2 to 400 Hz
nominal test current per phase< 3.5 mA
Weight and Dimensions IconWeight and Dimensions
dimensions5.1 x 2.7 x 1.3 inches (130 x 69 x 32 mm)
weight4.6 oz (130 g)
maximum operating voltage400 V