MN25 Version 2.2 Aug 2003
5
Specifications
Function Range Resolution Accuracy
200mV 0.1mV
2000mV 1mV
20V 0.01V
200V 0.1V
DC Voltage
(V DC)
600V 1V
± (0.5% reading + 2
digits)
200V 0.1V AC Voltage
(V AC)
600V 1V
± (1.5% reading + 5 digits
(Frequency 50/60Hz)
200mA
100µA
± (1.2% reading + 2
digits)
DC Current
(A DC)
10A 10mA
± (2.0% reading + 2
digits)
200mA
100µA
± (1.8% reading + 5
digits)
AC Current
(A AC)
10A 10mA
± (3.0% reading + 5
digits)
200Ω 0.1Ω
2000Ω 1Ω
20kΩ 0.01kΩ
200kΩ 0.1kΩ
± (0.8% reading + 2
digits)
Resistance
2000kΩ 1kΩ
± (1.0% reading + 2
digits)
9V 10mV Battery Test
1.5V 10mV
± (1.0% reading + 2
digits)
NOTE: Accuracy specifications consist of two elements:
• (% reading) – This is the accuracy of the measurement circuit.
• (+ digits) – This is the accuracy of the analog to digital
converter.
NOTE: Accuracy is stated at 65
o
F to 83
o
F (18
o
C to 28
o
C) and less
than 75% RH.