CHAPTER 27
PAGE 7
EXT
RA - FLUGZEUGBAU GmbH
SERVICE MANUAL EXTRA 200
PAGE DATE: 1. July 1996
27-01-01 Control Rod Removal/Installation
Refer to Figure 7. All control rods are attached to the control
levers in the same way with AN bolts, washers and self-
locking nuts. The control rods inside the wing are intercon-
nected by ground bonding leads fastened to the rod ends by
additional nuts. So the rod ends have to be disassembled,
when the ground bonding leads shall be disconnected. In
this case also refer to Chapter 27-01-06.
1 Remove the respective access panels.
N O T E In case of removal of the control rod connecting the con-
trol sticks also observe the instructions given in the
Chapters 27-01-03 and -04.
2 Remove the M6 attachment bolts (1).
3 Remove the control rod.
4 Reverse procedure to install the control rod. Replace
the selflocking nuts.
27-01-02 Bellcrank Removal/Installation
Refer to Figure 7
1 Remove the respective access panels.
2 Remove the adjacent control rods per Chapter 27-01-
01.
3 Remove the M5 attachment bolt (2).
4 Remove the bellcrank.
5 Reverse procedure to install the bellcrank using suffi-
cient washers (min. 2) at the nut side of the bolt to cover
the shank (except the rocker type bellcrank: use only
one washer on each side). Replace the selflocking nuts.
Observe the first Note of Chapter 27-01-00. To ensure
installation of the elevator rocker type bellcrank in cor-
rect direction this bellcrank is marked by an "F" which
indicates the front side (refer to Detail A of Figure 7).
MAINTENANCE PRACTICES