28-41-02 Fuel Quantity Indicator Calibration
(Center Tank)
1 Drain the fuel system (refer to Chapter 12-10-02).
2 Remove the fuel quantity indicator following step 2
of Chapter 28-41-01.
3 Bring indicator to 0-
position by turning the
adjustment screw.
4 Reinstall the fuel quantity indicator.
28-41-03 Tubular Tank Unit (Center Tank)
Removal/Installation
1 Drain the fuel system per Chapter 12-10-02.
2 Loosen one bolt and re-
place by a M5 threaded
rod (1) for securing the
slotted retainer ring (2).
3 Remove the other bolts
and the ground bonding
lead (3).
4 Lift tubular tank unit and sealing ring over the threaded
rod.
5 Remove the threaded rod
and turn out the slotted
retainer ring (2).
W A R N I N G Stripping solvents can be toxic and volatile. Use only in
well ventilated areas. Avoid physical contact with sol-
vent and do not inhale vapors. Keep solvent containers
covered when not in use.