PRODUCT DISPLAY TABLES
46
Chapter10
HIGH WATER TEMP
The circulation pump is
blocked.
Insu cient plant pressure.
Presence of air in the system.
Check the hydraulic plant pressure.
Bleed the air from the plant.
Switch o the machine, wait for complete cooling and repeat
the ignition cycle.
If the problem persists, the restoration operations must be
carried out by an authorised technician.
DOOR BLOCKED
The automatic cleaning of the
brazier results blocked.
Switch o the machine, wait for complete cooling and repeat
the ignition cycle.
If the problem persists, the restoration operations must be
carried out by an authorised technician.
COOLING WAIT +
ALARM
Attempt to release the alarm
with boiler still in cooling mode
Every time the boiler displays one of the alarms listed above it
will switch-o automatically.
The boiler will block any alarm release attempt during
this phase, showing the alarm itself and WAIT FOR COOL.
alternately on the display.
The alarm can only be released using button 1 when it switch-
o has been completed.