Do you have a question about the Extreme Networks ExtremeSwitching X670-G2-48x-4q and is the answer not in the manual?
Model | X670-G2-48x-4q |
---|---|
Product Type | Switch |
Form Factor | Rack-mountable |
Switching Capacity | 1.44 Tbps |
Jumbo Frame Support | Yes |
Storage Temperature | -40°F to 158°F (-40°C to 70°C) |
Humidity | 5% to 95% (non-condensing) |
AC Input Voltage | 100-240V AC |
AC Input Frequency | 50/60 Hz |
Maximum Power Consumption | 300W |
Forwarding Rate | 1071 Mpps |
MAC Address Table Size | 128, 000 entries |
Power Supply | 2 (Redundant) |
Dimensions (W x D x H) | 440 x 420 x 43 mm |
Operating Temperature | 0 to 40 °C |
Management | SNMP, CLI, Web-based management |
Features | sFlow |
Describes the X435 Series switches, including port details and features.
Introduces X440-G2 switches as cost-effective campus edge switches.
Details X450-G2 series switches, including port configurations and features.
Describes X460-G2 series switches, their ports, VIM options, and features.
Covers X465 series switches for enterprise LAN and aggregation applications.
Details X590 series switches for datacenter aggregation with 100 Gb uplinks.
Describes X620 series switches for 10 Gb edge applications with a 1 RU form factor.
Details steps for connecting switches, stacking cables, and management network.
Provides crucial safety information before installing or removing switches.
Details the process of mounting switches into racks or cabinets.
Provides instructions for installing internal power supplies into switches.
Explains how to connect AC and DC power sources to the switch.
Outlines initial setup, configuration, and login procedures.
Highlights safety precautions for installing external power supplies.
Provides instructions for installing the EPS-C2 redundant power system.
Details the installation of the RPS-150XT redundant power supply unit.
Covers the installation of the RPS-500p redundant power supply.
Explains the installation of the STK-RPS-150PS redundant power supply.
Provides instructions for installing the STK-RPS-1005PS redundant power supply.
Details the installation of the VX-RPS-1000 redundant power supply.
Provides instructions for replacing Summit 300 W AC power supplies.
Covers replacement of Summit 350 W and 715 W AC power supplies.
Details replacement of Summit 450 W and 550 W AC power supplies.
Provides instructions for replacing Summit 750 W AC power supplies.
Covers replacement of Summit 770 W AC power supplies.
Details replacement of Summit 1100 W AC power supplies.
Provides instructions for replacing ExtremeSwitching 2000 W AC power supplies.
Provides instructions for replacing Summit 300 W DC power supplies.
Details replacement of Summit 450 W and 550 W DC power supplies.
Provides instructions for installing replacement 450 W or 550 W DC power supplies.
Provides instructions for replacing 750 W internal DC power supplies.
Details installing a replacement 750 W DC power supply.
Provides instructions for installing 1100 W internal DC power supplies.
Details installing a replacement 1100 W DC power supply.
Provides step-by-step instructions for replacing a fan module.
Guides on removing or replacing V300 Virtual Port Extenders.
Details removing or replacing V400 Virtual Port Extenders.
Covers removal or replacement of LRM/MACsec Adapters.
Provides instructions for removing or replacing Half-Duplex to Full-Duplex Converters.
Guides on replacing VIMs, SSDs, or clock modules in X460-G2 and X465 switches.
Details the process of removing an AC power supply unit from a switch.
Provides instructions for removing a DC power supply unit from a switch.
Guides on safely removing a switch from a rack or cabinet.