EasyManua.ls Logo

Extron electronics AVT 200HD - Symbol Definitions for IP-Specific Commands

Extron electronics AVT 200HD
118 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AVT 200HD Tuner • Remote Configuration and Control 56
Symbol Definitions for IP-specific Commands
X4!
= Port number 0199 (represented as two ASCII characters with
leading zero if required
X4@
= Command data section Factory default name (model name + last 3 pairs of
MAC address)
X4#
= GMT offset –12.0 through +14.0. Represents hours and minutes
offset from Greenwich mean time (GMT).
X4%
= On and off status 0 = off or disabled
1 = on or enabled
X4^
= Dirty RAM status 0 = Random access memory has been saved to flash
memory (OK to power off or reset).
1 = RAM needs to be saved to flash memory
X5!
= Firmware version number n.nn (listed to two decimal places)
X5@
= Unit name Up to 24 characters: alphabetical (AZ or az), digits
(09), or hyphen (-).
NOTES: The following characters are invalid or not recommended in names:
{space} + ~ , @ = ` [ ] { } < > ‘ ’ “ ” ; : | \ and ?.
The first character must be alphabetical.
The last character must not be a hyphen.
X5#
= Local date and time format For setting:
In the format MM/DD/YY•HH:MM:SS
MM = month: 10 (January) through 12 (December)
DD = 01 through 31
YY = 00 through 99
HH = 00 through 23
MM = 00 through 59
SS = 00 through 59
For reading:
In the format Day,•DD•Mmm•YYYY•HH:MM:SS:
Day = weekday: Mon through Sun
DD = 01 through 31
Mmm = month: (Jan through Dec)
YYYY = year: 2000 through 2099
HH = 00 through 23
MM = 00 through 59
SS = 00 through 59
X5$
= IP address nnn.nnn.nnn.nnn
(Leading zeros in each of the four fields are optional
for setting values and are suppressed in returned
values.
Factory default address: 192.168.254.254
Default broadcast IP address: 255.255.255.255
X5^
= Power-up delay between ports in 1 through 255.
1/3 second increments. Default = 3, or 1 second.
X5&
= Time (in 10-ms increments) to wait 10 through 32767
for characters to come into a serial Default = 10, or 100 ms
port before terminating the
connection
X5*
= Time (in 10-ms increments) to wait 2 through 32767
between characters before Default = 2, or 20 ms
terminating the connection
X5(
= Hardware (MAC) address 00-05-A6-xx-xx-xx

Table of Contents

Other manuals for Extron electronics AVT 200HD