EasyManua.ls Logo

Extron electronics AVT 200HD - Page 63

Extron electronics AVT 200HD
118 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AVT 200HD Tuner • Remote Configuration and Control 57
X6)
= Subnet mask nnn.nnn.nnn.nnn
(Leading zeros in each of the four fields are optional
for setting values and are suppressed in returned
values.
Default = 255.255.0.0
X6!
= Message length, delimiter value, nL = Length of message to be received
or byte count (via the serial port). nD = Delimiter value
(This parameter is optional.) n = byte count (1 through 32767; default is 0)
Placed in front of the parameter (nD or nL)
X6@
= Verbose mode 0 = clear or none (default for Telnet connection)
1 = verbose mode (default for RS-232 connection)
2 = tagged responses for queries
3 = verbose mode and tagged responses for queries
NOTE: If tagged responses is enabled (modes 2 and 3), all read commands return the constant
string and the value as the set command does (for example, the read name command
E
CN
}
returns Ipn
X5@]
).
X6#
= Priority status for receiving timeouts 1 = use Send data string parameters (if they
exist) (default).
2 = use Configure receive timeout command
parameters instead.
X6$
= IP address converted into a single
32-bit number
Example: 10.13.0.254 becomes
(10*256*256*256) + (13*256*256) +
0*2456) + 254, which becomes (167,772,160 + 851,9678 + 254, which equals
68,624,382.
X6%
= Baud rate 9600 (default), 19200, 38400, 115200
X6^
= Parity Odd, Even, None (default), Mark, Space (Only the
first letter is required.)
X6&
= Data bits 7, 8 (default)
X6*
= Stop bits 1 (default), 2
X6(
= Port type 0 = RS-232 (default)
X7)
= Flow control Hardware, Software, None (default) (Only the first
letter is required.)
X7!
= Data pacing Specified in milliseconds between bytes:
0000 through 1000 (default = 0 ms)
X7@
= Password 12 characters maximum
NOTE: The following characters are invalid in passwords:
{space} + ~ , @ = ` [ ] { } < > ‘ ’ “ ” ; : | \ and ?.
X7#
= Daylight saving time 0 = off or ignore
1 = USA (Begins second Sunday in March and ends rst
Sunday in November.)
2 = Europe (Begins last Sunday in March and ends last
Sunday in October.)
3 = Brazil (Begins third Sunday in October and ends
third Sunday in February.)
X7$
= Event number 0 through 99 (event must be running)
X7%
= Event buffer 0 = receive
1 = unified
2 = data
3 = NVRAM
X7^
= Event buffer offset 0 through maximum buffer size

Table of Contents

Other manuals for Extron electronics AVT 200HD