AVT 200HD Tuner • Remote Configuration and Control 58
X7&
= Event data size b = bit
B = byte (8 bits)
S = short (16 bits)
L = long (32 bits)
NOTE: In a write operation, this parameter can optionally be preceded by A (for and) or O (for
or) to logically combine with content instead of replacing it.
X7*
= Event data to write
X7(
= Reading password Responds with **** if a password exists; the
response is empty if there is no password.
X8)
= Number of bytes to read 1 through 127
X8!
= E-mail event number/mailbox 1 through 64 (Response is returned as 3 digits with
leading zeros.)
X8@
= E-mail account 65 through 72
65 = email recipient 1, 66 = recipient 2, ...,
72 = recipient 8
X8#
= E-mail recipient address Typical e-mail address format
(for example: nnnn@xxx.com)
X8$
= Name of e-mail le to be sent The rst line of le is the subject; the rest is the body
(for CR command) of the e-mail.
Numeric name of e-mail file to be Format = nnn.eml. nnn = 1 through 999.
sent (for SM command)
X8%
= Default unit name Combination of the model name and the last three
pairs of the unit MAC address (for example,
AVT-200-HD-05-62-3D
X8*
= Security level of connection 11 = user
12 = administrator
X8(
= Time (in 10-ms increments) to wait 1 through 32767 (1=10 ms; 100 = 1000 ms = 1 second)
for receive data before releasing Default = 10, or 100 ms
port to another source (Response is returned with leading zeros.)
X9)
= ASCII digits representing numeric Leading zeros are suppressed.
value of data element read from
event buffer.
X9%
= Broadcast repetition rate in seconds 0 through 255
Default = 0 (clear)
(The response is returned with leading zeros.)
X9^
= Login allowed without password 0 = disabled
1 = enabled
X9*
= No-password login level 111 = entry without password goes to the level
specified, if an administrator password exists.
0 = entry without password is placed one level below
the lowest level that has a password (to 0-11).
The response is returned as 2 digits with leading zero.
X9(
= Number of seconds before IP 1 through 65000
connection timeout Default = 30 = 300 seconds
X10#
= Hardware (MAC) address with
the 4 most signicant hex
nibbles converted into a single
16-bit decimal number.
X10$
= Hardware (MAC) address with Can be up to 10 digits.
the 8 least signicant hex
nibbles converted into a single
32-bit decimal number.