Error 93: Scour Tank Recharge Timeout
TRIGGER: Scour Heater minimum recharge ow of 15mL was not reached within 8 seconds
1. Reset the blender by pressing “Regular” & “More Thick” buons together for 7 seconds to so-reset the blender.
2. Ensure blender has the latest Firmware Version.
A. Press the “Le Arrow” & “OK” buons for 7 seconds unl the Status Screen appears on the screen. Locate “FWXXXX” in
the top right corner. FW Version should be FW0330.
3. Ensure water supply is on and regulated to 25 - 65 PSI.
4. Verify Water Pressure Regulator is installed correctly with an arrow poinng in the direcon of the water ow. If damaged,
replace Water Pressure Regulator (Parts Manual: Glossary).
A. SN 19783D and later will have an Internal Water Pressure Regulator.
5. Remove the Lower Scour Nozzle and clean as necessary. When cleaning, be sure not to enlarge the opening of the nozzle.
Enlarging the nozzle will result in a dierent spray paern, compromising the blender’s ability to clean itself. When the nozzle is
removed, close the front door and so-reset to ush any debris from the line. Replace nozzle and so-reset again.
6. If errors persist, replace the Manifold (Parts Manual: Water System).
Error 94: Steamer Thermal Shock Timeout
TRIGGER: Steamer thermal shock water event exceeded 30 seconds for 55mL of water
1. Reset the blender by pressing “Regular” & “More Thick” buons together for 7 seconds to so-reset the blender.
2. Ensure water supply is on and regulated to 25 - 65 PSI.
3. Inspect Water Shot Orice (WSO) for scale buildup. Use a paperclip or similar item to clean the WSO. In some cases, removing
the Water Shot Hose connecon at the top of the blending chamber is necessary to completely clean the WSO.
4. If there are no signs of scale buildup and the blender has been subjected to water pressure greater than 65 PSI, replace
Manifold (Parts Manual: Water System).
5. Check the amount of water ow coming from the water shot hose.
A. Remove the water shot hose from the back of the blending chamber.
B. Bring up the LVCBS Status Screen (Press the “Le Arrow” & “OK” buons for 7 seconds unl the Status Screen appears on
the screen) and locate Line J: “Count XXXX mL”
a. If the amount in the cup is either less or more than what is on the “Count XXXX mL”, replace Flow Meter (Parts
Manual: Water System).
Error 95: Parameter Chucksum aer Reading EEPROM
TRIGGER: At start-up, if parameter check fails
1. Reset EEPROM.
A. To reset EEPROM, turn the blender o using the power switch and ensure there is no cup in the Cup Holder.
B. Press and hold the ‘le’ and ‘right’ arrow keys together and turn the blender on.
C. Connue to hold the arrow keys down unl the video/animaon starts to play.
D. Try another blend cycle. If error persists, replace the Low Voltage Control Board (Parts Manual: Control Boards, Lower).
Error 96: Extended Water Shot too Short in Duraon
TRIGGER: The target volume of 5,000mL was reached faster than 10 seconds
1. Reset the blender by pressing “Regular” & “More Thick” buons together for 7 seconds to so-reset the blender.
2. Check for any connuous leaks inside the blender. If any nozzles or orices are running with the door open, replace Manifold
(Parts Manual: Water System).
3. Inspect the Water Shot Orice inside the chamber. Ensure this is not damaged in any way. If it is, replace Chamber Assembly
(Parts Manual: Inside the Chamber).
Error 97: Extended Water Shot too Long in Duraon
TRIGGER: The target volume of 5,000mL was not reached in 900 seconds during water system purge
1. Reset the blender by pressing “Regular” & “More Thick” buons together for 7 seconds to so-reset the blender.
2. Ensure water supply is on and regulated to 25 - 65 PSI.
3. Verify Water Pressure Regulator is installed correctly with an arrow poinng in the direcon of the water ow. If damaged,
replace Water Pressure Regulator (Parts Manual: Glossary).
A. SN 19783D and later will have an Internal Water Pressure Regulator.
4. Inspect Water Shot Orice (WSO) for scale buildup. Use a paperclip or similar item to clean the WSO. In some cases, removing
the Water Shot Hose connecon at the top of the blending chamber is necessary to completely clean the WSO.
5. If there are no signs of scale buildup and the blender has been subjected to water pressure greater than 65 PSI, replace
Manifold (Parts Manual: Water System).