Error 93: Scour Tank Recharge Timeout
TRIGGER: Scour Heater minimum recharge ow of 15mL was not reached within 8 seconds
1. Reset the blender by pressing “Regular” & “More Thick” buons together for 7 seconds to so-reset the blender.
2. Ensure blender has the latest Firmware Version.
A. Press the “Le Arrow” & “OK” buons for 7 seconds unl the Status Screen appears on the screen. Locate “FWXXXX” in
the top right corner. FW Version should be FW0330.
3. Ensure water supply is on and regulated to 25 - 65 PSI.
4. Verify Water Pressure Regulator is installed correctly with an arrow poinng in the direcon of the water ow. If damaged,
replace Water Pressure Regulator (Parts Manual: Glossary).
A. SN 19783D and later will have an Internal Water Pressure Regulator.
5. Remove the Lower Scour Nozzle and clean as necessary. When cleaning, be sure not to enlarge the opening of the nozzle.
Enlarging the nozzle will result in a dierent spray paern, compromising the blender’s ability to clean itself. When the nozzle is
removed, close the front door and so-reset to ush any debris from the line. Replace nozzle and so-reset again.
6. If errors persist, replace the Manifold (Parts Manual: Water System).
Error 94: Steamer Thermal Shock Timeout
TRIGGER: Steamer thermal shock water event exceeded 30 seconds for 55mL of water
1. Reset the blender by pressing “Regular” & “More Thick” buons together for 7 seconds to so-reset the blender.
2. Ensure water supply is on and regulated to 25 - 65 PSI.
3. Inspect Water Shot Orice (WSO) for scale buildup. Use a paperclip or similar item to clean the WSO. In some cases, removing
the Water Shot Hose connecon at the top of the blending chamber is necessary to completely clean the WSO.
4. If there are no signs of scale buildup and the blender has been subjected to water pressure greater than 65 PSI, replace
Manifold (Parts Manual: Water System).
5. Check the amount of water ow coming from the water shot hose.
A. Remove the water shot hose from the back of the blending chamber.
B. Bring up the LVCBS Status Screen (Press the “Le Arrow” & “OK” buons for 7 seconds unl the Status Screen appears on
the screen) and locate Line J: “Count XXXX mL”
a. If the amount in the cup is either less or more than what is on the “Count XXXX mL”, replace Flow Meter (Parts
Manual: Water System).
Error 95: Parameter Chucksum aer Reading EEPROM
TRIGGER: At start-up, if parameter check fails
1. Reset EEPROM.
A. To reset EEPROM, turn the blender o using the power switch and ensure there is no cup in the Cup Holder.
B. Press and hold the ‘le’ and ‘right’ arrow keys together and turn the blender on.
C. Connue to hold the arrow keys down unl the video/animaon starts to play.
D. Try another blend cycle. If error persists, replace the Low Voltage Control Board (Parts Manual: Control Boards, Lower).
Error 96: Extended Water Shot too Short in Duraon
TRIGGER: The target volume of 5,000mL was reached faster than 10 seconds
1. Reset the blender by pressing “Regular” & “More Thick” buons together for 7 seconds to so-reset the blender.
2. Check for any connuous leaks inside the blender. If any nozzles or orices are running with the door open, replace Manifold
(Parts Manual: Water System).
3. Inspect the Water Shot Orice inside the chamber. Ensure this is not damaged in any way. If it is, replace Chamber Assembly
(Parts Manual: Inside the Chamber).
Error 97: Extended Water Shot too Long in Duraon
TRIGGER: The target volume of 5,000mL was not reached in 900 seconds during water system purge
1. Reset the blender by pressing “Regular” & “More Thick” buons together for 7 seconds to so-reset the blender.
2. Ensure water supply is on and regulated to 25 - 65 PSI.
3. Verify Water Pressure Regulator is installed correctly with an arrow poinng in the direcon of the water ow. If damaged,
replace Water Pressure Regulator (Parts Manual: Glossary).
A. SN 19783D and later will have an Internal Water Pressure Regulator.
4. Inspect Water Shot Orice (WSO) for scale buildup. Use a paperclip or similar item to clean the WSO. In some cases, removing
the Water Shot Hose connecon at the top of the blending chamber is necessary to completely clean the WSO.
5. If there are no signs of scale buildup and the blender has been subjected to water pressure greater than 65 PSI, replace
Manifold (Parts Manual: Water System).