EasyManua.ls Logo

F'real FRLB6 - User Manual

F'real FRLB6
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
Rev. D
Model: FRLB6
Service Manual
Question and Answer IconNeed help?

Do you have a question about the F'real FRLB6 and is the answer not in the manual?

Summary

Blender Maintenance Procedures

Daily Blender Maintenance Steps

Covers daily cleaning tasks for the blender, including visual inspection and surface wiping.

Weekly Blender Maintenance Steps

Details weekly cleaning procedures for seals, chamber openings, and cup sensors.

Main Menu Operations

Accessing the Main Menu

Instructions on how to navigate and access the blender's main menu interface.

Main Menu Options Overview

Description of the different tabs and options available within the main menu.

Resetting Blender Error Codes

Procedure for clearing error codes through the main menu system.

Blender Error Codes Troubleshooting

Error 64: Mix Motor Peak Current Limit

Troubleshooting for mix motor peak current limit exceeded.

Error 65: Position Motor Peak Current Limit

Troubleshooting for position motor peak current limit exceeded.

Error 66: Pump Motor Peak Current Limit

Troubleshooting for pump motor peak current limit exceeded.

Error 67: Blend Time-Out

Troubleshooting for any blend routine time-out parameter exceeded.

Error 75: Sanitize Sequence Timeout

Troubleshooting for the sanitize sequence timing out.

Error 77: Steamer Heater Temperature Out of Range

Troubleshooting for steamer heater temperature outside allowable range.

Error 85: Steamer Heater Temperature Control

Troubleshooting for steamer heater temperature control errors.

Error 86: Scour Heater Temperature Control

Troubleshooting for scour heater temperature control errors.

Error 91: Mix Motor FET Destroyed

Troubleshooting for mix motor FET destroyed error.

Error 92: Pump Motor FET Destroyed

Troubleshooting for pump motor FET destroyed error.

Error 9 A: Chamber Temp Sensor Differential Limit

Troubleshooting for chamber temperature sensor differential limit exceeded.

Error 9 D: End-Stop Detected Early

Troubleshooting for end-stop detection failure in calibration sequence.

Error A0: Chamber Too Cold

Troubleshooting for chamber temperature being too low.

Error A2: Flip-Up Door Open During Blend End

Troubleshooting for flip-up door misalignment at end of blend cycle.

Consumer Error Messages

Cup Lid Removal Error

Customer guidance for ensuring the cup lid is completely removed before blending.

Front Door Status Error

Guidance for ensuring the front door is properly closed and latched.

Flip-Up Door Open Error

Troubleshooting for the flip-up door opening at unexpected times.

Cup Holder Obstruction Error

Addressing obstructions that prevent the cup holder from moving freely.

Incorrect Cup Size Used Error

Guidance on using the correct cup size for the blender.

Product Temperature Issue

Addressing issues where the product is not cold enough to blend.

Blender Water Level Error

Troubleshooting when the blender indicates it needs water to blend.

Blending Chamber Obstruction

Guidance on removing obstructions from the underside of the blending chamber.

Cup Holder Timeout Error

Addressing the error when a cup is left in the holder too long after blending.

Other Blender Issues

Front Door Issues

Troubleshooting for problems with the front door not closing or opening correctly.

Front Door Water Leaks

Diagnosing and fixing water leaks from the front door area.

Mixer Grinding Noise

Troubleshooting unusual grinding noises during the blending process.

Beverage Consistency Issues

Addressing blended beverages that are too thin or too thick.

Cup Sensor Issues

Troubleshooting for problems with the cup placement and size sensor circuits.

F'real FRLB6 Specifications

General IconGeneral
ModelFRLB6
TypeBlender
Voltage120V
MaterialStainless Steel
ColorSilver