19
ENGLISHENGLISH
LOGICS "A"
PULSES
GATE STATUS
OPEN-A
OPENING/CLOSING SAFETIESCLOSING SAFETIESOPENING SAFETIES
STOP
Table 5/a
CLOSED
OPEN on PAUSE
CLOSING
OPENING
No effect
No effect (OPEN inhibited)
Stops closing and, when disengaged,
opens
See paragraph 4.2.2
Stops opening and, when disengaged,
continues to open
No effect
No effect
No effect (OPEN inhibited)
No effect
No effect (OPEN inhibited)
STOPPED
Freezes pause until disengagement (*1) (OPEN inhibited)
No effect
No effect (OPEN inhibited)
No effect (OPEN inhibited)Closes leaf/leaves
LOGICS "S"
GATE STATUS
OPEN-A
OPENING/CLOSING SAFETIESCLOSING SAFETIESOPENING SAFETIES
STOP
PULSES
Table 5/b
OPEN on PAUSE
CLOSING
No effect (OPEN inhibited)
OPENING
Freezes pause until disengagement (*1) (OPEN inhibited)
No effect (OPEN inhibited)
See paragraph 4.2.2
Stops opening and, when disengaged,
continues to open
No effect
Stops closing and, when disengaged,
opens
STOPPED
Closes leaf/leaves
No effect
No effect (OPEN inhibited)
CLOSED
No effect (OPEN inhibited)
No effect
LOGICS "E"
GATE STATUS
OPEN-A CLOSING SAFETIESOPENING SAFETIES
STOP
Table 5/c
Stops
CLOSED
Opens leaves
No effect (OPEN inhibited)
No effect
No effect (OPEN inhibited)
OPENING
No effect (OPEN inhibited)
Stops closing and, when disengaged,
opens
See paragraph 4.2.2
Stops opening and, when disengaged,
continues to open
No effect
Stops
No effect (OPEN inhibited)
Closes leaf/leaves
No effect (OPEN inhibited)
No effect
No effect (OPEN inhibited)
No effect
STOPPED
CLOSING
OPEN
Table 5/d
LOGICS "EP"
PULSES
GATE STATUS
OPEN-A
No effect (OPEN inhibited)
OPENING/CLOSING SAFETIESCLOSING SAFETIESOPENING SAFETIES
STOP
CLOSED
Opens leaves
No effect (OPEN inhibited) No effect
OPEN
CLOSING
Stops closing and, when disengaged,
opens
See paragraph 4.2.2
Stops
Recloses leaf immediately
No effect
No effect (OPEN inhibited)
Inverts the direction
STOPPED
OPENING
Stops
No effect
(if the gate must open, inhibits OPEN)
No effect
(if gate must close, inhibits OPEN)
No effect
Stops opening and, when disengaged,
continues to open
Opens leaves and recloses after pause time
Recloses leaves immediately
Reopens leaves immediately
Opens leaves and recloses after pause time
No effect
Recloses leaves immediately
Reopens leaves immediately
Recloses leaves immediately
Recloses leaves immediately
Reopens leaves immediately
PULSES
OPENING/CLOSING SAFETIES
Stops opening and, when disengaged, closes
No effect (OPEN inhibited)
No effect (OPEN inhibited)
No effect (OPEN inhibited)
Stops
Stops
Stops
Stops opening and, when disengaged, closes
Stops opening and, when disengaged, closes
Stops opening and, when disengaged, closes
(*1) If residual pause time is less than 5 seconds on safety disengagement, the gate closes after 5 seconds.
N.B.: Effects of other active impulse inputs are shown in brackets