18
ENGLISH ENGLISH
Table 3 - Current drawn by accessories
N.B. Use a dedicated decoder for each accessory type.
ACCESSORY CURRENT DRAWN
R 31 50 mA
PLUS 433 E 20 mA
MINIDEC SL / DS 6 mA
DECODER SL / DS 20 mA / 55 mA
RP 433 SL / DS 12 mA / 6 mA
DIGICARD 15 mA
METAL DIGIKEY 15 mA
FOTOSWITCH 90 mA
DETECTOR F4 / PS6 50 mA
MINIBEAM 70 mA
4.2. PROGRAMMING THE MICROSWITCHES
Automation programming is carried out by the microswitches
(fig. 13 - ref. 9) as shown in the diagram below.
OPERATING
LOGICS
SAFETIES ON CLOSING
INVERTS MOVEMENT
IMMEDIATELY
STOPS AND INVERTS
MOVEMENT ON
DISENGAGEMENT
4.2.1. OPERATION LOGICS
There are four operating logics available:
A: “AUTOMATIC ” E : “SEMI-AUTOMATIC”
S : “SAFETY” EP : “SEMI-AUTOMATIC STEP-BY-STEP”
Operation of the different logics is described in tables
5/a-b-c-d.
4.2.2. SAFETIES ON CLOSING
This function serves to select the operating mode for the
closing safeties:
- OFF: immediate reverse of movement during gate closure
- ON: movement is stopped during closing and reversed on
opening when the safety is disengaged.
5. START-UP
1) Programme the 410 MPS control unit to set the specific
installation requirements as shown in paragraph 4.2.
2) Check led status as shown in table 4.
Table 4: LED functions
LEDS ON OFF
D 1 (OPEN INPUT A) Command active Command not active
D 3 (STOP) Command not active Command active
D 4 (FTSW OPEN) Safeties disengaged Safeties engaged
D 5 (FTSW CLOSE) Safeties disengaged Safeties engaged
N.B.: the bold text indicates led status with gate idle.
5.1. DIRECTION OF ROTATION
1) Switch off the power.
2) Release the operators and move the gate manually to its
mid-travel position.
3) Lock the operators.
4) Fit the protection plug supplied with the operator release
system.
5) Switch on the power.
6) Send an OPEN signal to input A (fig. 14) and check that the
leaf opens.
If the gate closes, invert the motor wires on the control unit
(brown and black wires).
Fig. 23
Fig. 22
MINIDEC
SL/DS
PLUS
433 E
410 MPS
410 MPS
DECODER
SL
410 MPS
410 MPS
Fig. 24
Fig. 25