EasyManua.ls Logo

FAAC 940SM Series - User Manual

FAAC 940SM Series
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
940SM-SMD
940SM-SMD
para la naturaleza
100% papel reciclado
ist umweltfreundlich
100% Altpapier
pour la nature
papier recyclé 100%
for nature
recycled paper 100%
carta riciclata 100%
per la natura

Questions and Answers

  • M
    Mary SaundersAug 18, 2025
    What to do if my FAAC 940SM Gate Opener door is not closing and the ERROR LED is off?
    • M
      michaellaneAug 19, 2025
      If your door is not closing and the ERROR LED is off, consider the following: * Check if the photocell/s are engaged. Also, verify that the selected operating function is not DOOR OPEN. If there is no SD-Keeper installed, ensure that input 8 of the J6 terminal board is not jumper connected to the negative. * Make sure that the selected operating function is not MANUAL. * Check the motor connection. * Check if power is being supplied to the motor (VMOT LED ON).
  • C
    Charles AguilarAug 20, 2025
    What to do if my FAAC 940SM Gate Opener door is not opening and the ERROR LED is off?
    • P
      pearsonreneeAug 21, 2025
      If the door is not opening and the ERROR LED is off: * Make sure that the selected operating function is not MANUAL. * Ensure that the selected operating function is not set to NIGHT. If there is no SD-Keeper installed, make sure that input 7 of the J6 terminal board is not jumper connected to the negative. * Check the motor connection. * Make sure that the lock is not locked. * Check if power is being supplied to the motor (VMOT LED ON).
  • J
    johnsonlawrenceAug 23, 2025
    Why is my FAAC 940SM Gate Opener door closing instead of opening, or vice versa?
    • M
      Michael RodriguezAug 23, 2025
      If your gate opener door closes instead of opening (or vice versa), reverse the position of dip-switch 1 on the 940SDM control board and execute a SETUP.
  • C
    Christine MasonAug 26, 2025
    What to do if my FAAC 940SM Gate Opener door is not executing SETUP and the ERROR LED is flashing slowly?
    • B
      Brian PriceAug 26, 2025
      If your FAAC gate opener door is not executing SETUP and the ERROR LED is flashing slowly, consult the 940SDM control board instructions for guidance on SETUP execution.
  • J
    John MartinAug 27, 2025
    Why are the MAIN, VACC, VMOT and +24V LEDs off on my FAAC Gate Opener?
    • G
      griffithleahAug 28, 2025
      If the MAIN, VACC, VMOT, and +24V LEDs are off, it could be due to several reasons: * The F2 5x20 T1A fuse on the 940SDM control board may be interrupted. Check this fuse. * The 5x20 T1A fuse inside the power supply unit could be interrupted. Check this fuse. * Connector J2 might not be fitted correctly on the 940SDM control board. Ensure it is properly connected. * The 940SDM control board itself may not be operating correctly, requiring replacement.
  • R
    Rebecca SloanAug 30, 2025
    Why is the MAIN LED off but VACC, VMOT and +24V LEDs are on in my FAAC 940SM?
    • H
      Heather ClarkAug 30, 2025
      If the MAIN LED is off, but the VACC, VMOT, and +24V LEDs are on, it indicates that mains power is not supplied and the 940SDM control board is running on battery power. Check the mains power supply.
  • P
    Paul Riggs MDSep 1, 2025
    Why is VMOT LED off but MAIN, VACC and +24V LEDs are on in my FAAC 940SM Gate Opener?
    • C
      Calvin HebertSep 1, 2025
      If the VMOT LED is off while the MAIN, VACC, and +24V LEDs are on, it could indicate: * The F1 5x20 T6.3A fuse on the 940SDM control board is interrupted. Check the fuse. * Connector J3 is not correctly fitted on the 940SDM control board. Check the connection. * The 940SDM control board is not operating correctly and may need to be replaced.
  • M
    Michael NelsonSep 3, 2025
    What does it mean if VMOT and VACC LEDs are off but MAIN and +24V LEDs are on in my FAAC 940SM Gate Opener?
    • J
      Jacob MendezSep 4, 2025
      When the VMOT and VACC LEDs are off, but the MAIN and +24V LEDs are on, it typically means: * The control board software is being updated; wait for the procedure to finish. * There may be condensation on the board; cut power and dry the dampness. * The 940SDM control board may not be operating correctly and needs replacement.
  • M
    Monique StokesSep 6, 2025
    Why is the SD-KEEPER off on my FAAC 940SM Gate Opener?
    • R
      Rachel SandersSep 6, 2025
      If the SD-KEEPER is off, it could be due to the following reasons: * No mains power is supplied, and the 940SDM control board is battery-powered in NIGHT operating function and in energy-saving status. Check the connection cables and wiring between the SD-Keeper and the 940SDM control board. * The connection to the 940SDM control board is interrupted. Check the connection cables and wiring between the SD-Keeper and the 940SDM control board. * The 940SDM control board is not operating correctly. Consider replacing the 940SDM control board.
  • M
    mcfarlandmeganSep 8, 2025
    What to do if my FAAC 940SM Gate Opener door is locked and the ERROR LED is on?
    • D
      Dennis LambertSep 8, 2025
      If the door is locked and the ERROR LED is on, execute SETUP.

Summary

CE DECLARATION OF CONFORMITY FOR MACHINES

WARNINGS FOR THE INSTALLER

General safety obligations for installers, emphasizing caution and correct procedures.

KEY TO PROFILES

SUPPORT PROFILE

The primary profile used when the head profile can be fixed to a bearing structure.

HOUSING PROFILE

Encloses the system, available in natural or anodised aluminium.

SLIDING PROFILE

Profile coated with plastic for silent operation and low friction.

CLOSING PROFILE FOR STANDARD AUTOMATED SYSTEM

Closes the space between the mobile leaf and the wall.

LEAF ATTACHMENT PROFILE

Attaches the top leaf profile to the carriage attachments.

LEAF BOTTOM PROFILE

Adapts the bottom leaf profile to the sliding block.

GRIPPER FOR GLASS LEAVES

Secures glass leaves to the carriage.

BOTTOM SLIDING BLOCK FOR GLASS LEAF

Secures to the wall or floor for glass leaves.

1. TECHNICAL SPECIFICATIONS

AVAILABLE MODELS

Details available models like 940SM1, 940SM2, 940SMD1, 940SMD2.

1. ELECTRICAL EQUIPMENT

Lists electrical components and their specifications for installation.

2. DESCRIPTION AND TECHNICAL SPECIFICATIONS

Profile SM

Support profile for bearing structures, with low friction sliding track.

Motor unit

DC motor unit supplied with an encoder and leaf locking system.

Motor lock unit

Guarantees mechanical locking of the door in any position.

3. ACCESSORIES

3.1 Supplied accessories for the head profile

Accessories assembled on the head profile directly by FAAC.

3.2 Supplementary accessories

Peripheral accessories to complete the automated system.

3.3 Door frame accessories

Articles to adapt the door frame profile to carriages.

4. HEAD PROFILE CONFIGURATION

5. INSTALLATION

6. SECURING THE HEAD PROFILE

Steps for securing the head profile to a bearing structure.

6.1 Installation of side panels

How to fit the side panels onto the head profiles.

7. INSTALLATION OF BOTTOM SLIDING BLOCKS

Securing on the wall (or on stationary leaf)

Procedure for securing sliding blocks to the wall or stationary leaf.

Securing on the floor

Procedure for securing sliding blocks directly to the floor.

8. INSTALLATION OF THE LEAVES

8.1 Leaf adjustment

8.2 Adjustment of the counter roller

9. ADJUSTMENT OF THE TRAVEL STOP LIMITS

Adjustment of the opening mechanical stops

How to set the mechanical stops for the opening travel.

Adjustment of the closing mechanical stop.

How to set the mechanical stops for the closing travel.

10. BELT ADJUSTMENT

11. INSTALLATION OF HOUSING FIXING BRACKETS

12. MOTOR LOCK

12.1 Installation of internal release knob

12.2 Motor lock adjustment

13. FITTING THE HOUSING

14. INSTALLATION OF CABLE SLEEVES

15. INSTALLATION OF BUFFER BATTERIES

16. INSTALLATION WITH GRIPPERS FOR GLASS LEAVES

17. START-UP

940 SDM CONTROL BOARD

SECOND MOTOR CONTROL BOARD

TERMINAL BOARD J6

TERMINAL BOARD J5

CONNECTION OF PHOTOCELLS WITH FAILSAFE DISABLED (DEFAULT)

CONNECTION OF PHOTOCELLS WITH FAILSAFE ENABLED

DESCRIPTION OF TERMINALS

TERMINAL BOARD J5

Detailed description of each terminal on board J5.

J6 TERMINAL BOARD

Detailed description of each terminal on board J6.

MOTOR ROTATION DIRECTION

How to set the motor rotation direction using dip-switches.

START-UP

STANDARD CONFIGURATION

PHOTOCELLS

SETUP

RESET

SPEED CHANGES

BEHAVIOUR UNDER DIFFERENT OPERATING FUNCTIONS

OPERATING FUNCTIONS

SPECIAL FUNCTIONS

SETUP

Door initialisation function for self-learning parameters.

RESET

Restores normal operation after alarms.

LOCK

Function to disable SD-Keeper by activating a key combination.

BATTERY INSERTION;CHANGE

Procedure for inserting or changing the SD-Keeper battery.

FLOW-CHART SD-KEEPER

1 LANGUAGE

2 SETUP

2.1 PARTIAL OPENING

Selects the opening percentage for partial opening function.

2.2 PAUSE TIME

Enables or disables pause time in automatic function.

2.3 NIGHT PAUSE TIME

Sets pause time for the night operational function.

2.4 ANTI-INTRUDER

Controls door resistance to manual opening attempts.

2.5 OBSTACLE DETECTION

Configures how the door reacts to obstacles during operation.

3 BATTERY

3.1 BATTERY KIT

Enables or disables the battery kit installation.

3.2 BAT. OPERATION

Defines door behaviour during battery operation.

3.3 LAST OPERAT.

Selects the last movement operation during battery power.

3.4 NIGHT BATT.

Configures night function behaviour during power cuts.

4 LOCK

4.1 KIT LOCK

Enables or configures the lock operation modes.

4.2 NIGHT LOCK

Controls lock behaviour during night function with low battery.

4.3 SURVEILLANCE

Enables surveillance of the lock's efficiency.

2.6 OUT 1

2.7 OUT 2

2.8 OUT 3

3 VARIOUS

3.1 Stand Setup

Checks if non-standard programming was done; resets to standard.

3.2 Interlock

Configures interlock function between two doors (master/slave).

3.3 Kit elastic.

Enables or disables the elastic kit for anti-panic opening.

4 CHANGE PASSWORD

LOCK SURVEILLANCE

ANTI-PANIC WITH ELASTIC

ANTI-PANIC BY BREAK-OUT

ACCESSORIES

LOCK

Procedure for installing the lock card and making connections.

INTERLOCK

INTERLOCK WITH INTERNAL SENSORS

Application for doors with sufficient distance between internal sensors.

INTERLOCK WITHOUT INTERNAL SENSORS

Application for doors where internal sensors cannot be used.

DIAGNOSTICS GUIDE

TROUBLESHOOTING

FAAC 940SM Series Specifications

General IconGeneral
Model940SM Series
Motor Power300 W
Power300 W
Current1.3 A
Safety DevicesPhotocells, safety edges
Operating Temperature-20°C to +55°C
Power Supply230V AC
LockingElectromechanical