What to do if my FAAC 940SM Gate Opener door is moving for short distances only?
What to do if my FAAC 940SM Gate Opener door is moving for short distances only?
Model | 940SM Series |
---|---|
Motor Power | 300 W |
Power | 300 W |
Current | 1.3 A |
Safety Devices | Photocells, safety edges |
Operating Temperature | -20°C to +55°C |
Power Supply | 230V AC |
Locking | Electromechanical |
Manual Release | Yes |
General safety obligations for installers, emphasizing caution and correct procedures.
The primary profile used when the head profile can be fixed to a bearing structure.
Encloses the system, available in natural or anodised aluminium.
Profile coated with plastic for silent operation and low friction.
Closes the space between the mobile leaf and the wall.
Attaches the top leaf profile to the carriage attachments.
Adapts the bottom leaf profile to the sliding block.
Secures glass leaves to the carriage.
Secures to the wall or floor for glass leaves.
Details available models like 940SM1, 940SM2, 940SMD1, 940SMD2.
Lists electrical components and their specifications for installation.
Support profile for bearing structures, with low friction sliding track.
DC motor unit supplied with an encoder and leaf locking system.
Guarantees mechanical locking of the door in any position.
Accessories assembled on the head profile directly by FAAC.
Peripheral accessories to complete the automated system.
Articles to adapt the door frame profile to carriages.
Steps for securing the head profile to a bearing structure.
How to fit the side panels onto the head profiles.
Procedure for securing sliding blocks to the wall or stationary leaf.
Procedure for securing sliding blocks directly to the floor.
How to set the mechanical stops for the opening travel.
How to set the mechanical stops for the closing travel.
Detailed description of each terminal on board J5.
Detailed description of each terminal on board J6.
How to set the motor rotation direction using dip-switches.
Door initialisation function for self-learning parameters.
Restores normal operation after alarms.
Function to disable SD-Keeper by activating a key combination.
Procedure for inserting or changing the SD-Keeper battery.
Selects the opening percentage for partial opening function.
Enables or disables pause time in automatic function.
Sets pause time for the night operational function.
Controls door resistance to manual opening attempts.
Configures how the door reacts to obstacles during operation.
Enables or disables the battery kit installation.
Defines door behaviour during battery operation.
Selects the last movement operation during battery power.
Configures night function behaviour during power cuts.
Enables or configures the lock operation modes.
Controls lock behaviour during night function with low battery.
Enables surveillance of the lock's efficiency.
Checks if non-standard programming was done; resets to standard.
Configures interlock function between two doors (master/slave).
Enables or disables the elastic kit for anti-panic opening.
Procedure for installing the lock card and making connections.
Application for doors with sufficient distance between internal sensors.
Application for doors where internal sensors cannot be used.