The 760 Gate Automation System
The FAAC 760 automation system consists of a monoblock hydraulic unit and foundation
box assembly. The system is designed for underground installation, and will not alter the
appearance of the gate.
CONTENTS
1. Typical Installation Schematic
2. Technical Specifications
3. Description and Technical Specification
3.1 Maximum Duty Cycle Curve
4. Installation
4.1 Preliminary checks
4.2 Installation of leaf supporting foundation box
4.3 Setting up the gate
5. Start-up
5.1 Adjustment of the anti-crushing device
5.2 Adjustment of the internal travel stop screws (760 CR only)
5.3 Adjustment of deceleration ramp (760 CR only)
6. Angles of operation below 90°
7. Manual operation
8. Maintenance
General Safety Standards
Read the instructions carefully before installing the gate automation system. Keep these instructions for future reference.
Installation, electrical wiring and adjustments must be carried out in compliance with current safety standards.
FAAC cannot be held responsible for failure to observe technical standards in the construction of gates, or for any deformation of the gates
which may occur during use.
Before installing the gate automation system, make all necessary structural modifications to ensure safety clearances, and for the protection
and/or isolation of all cutting, entrapment, and crushing areas.
This equipment should be defined only to the use for which it has been expressly conceived (all equipment), any other use should be
considered improper and therefore dangerous. The manufacturer cannot be held responsible for eventual damage caused by improper,
incorrect and unreasonable use.
Do not use this device in areas subject to explosion: the presence of flammable gases or fumes is a serious hazard.
Before carrying out any cleaning or maintenance operations, unplug the equipment from the electrical supply network either by removing
the plug or by turning off the system’s main switch.
An isolation switch should be provided for the installation according to by current safety regulations with an opening distance of 3 mm or
more on the part of the contacts. Alternatively, use a 6A thermo-magnetic breaker with multi-pole switching.
Ensure that there is a differential switch up-line of the electrical system, with a trip threshold of 0.03A.
Check that the earthing plant is in perfect condition and connect it to the gate frame. Also earth the yellow/green wire of the operator.
The end-user must avoid any attempt to repair or adjust the automation system; these operations must be carried out exclusively by
qualified personnel.
Use only FAAC original spare parts for maintenance operations.
Do not carry out any modifications to automation components.
•Packaging material (plastic, polystyrene etc.) is a potential hazard and must be kept out of reach of children
The installer must supply all information regarding manual operation of the system in the event of an emergency and provide the end-user
with the leaflet attached to the product.
The operator is fitted with an anti-crush safety system, this is a torque control device which guarantees ultimate safety and reliability if properly
adjusted
In any event, FAAC always recommends the installation of other safety devices, taking into consideration current safety standards, installation
site, system operation logics, dimensions and weight of the gate.
The safety devices (e.g photocells, safety edges, etc.) will protect the crushing and entrapment areas and general potential hazard areas of
the automation.
Each installation must be fitted with at least one flashing light (e,g, FAAC LAMP, MINILAMP etc,) as well as a warning plate suitably fixed to the
gate.
•FAAC UK Ltd. accepts no responsibility for damage or injury resulting from the incorrect use of this gate automation system.
VSS LIMITED
Sales@vssystems.co.uk
0800 018 2324

Other manuals for FAAC 760

Question and Answer IconNeed help?

Do you have a question about the FAAC 760 and is the answer not in the manual?

FAAC 760 Specifications

General IconGeneral
BrandFAAC
Model760
CategoryGate Opener
LanguageEnglish

Summary

General Safety Standards

Typical Installation Schematic

Technical Specifications

Description and Technical Specifications

Maximum Duty Cycle Curve

Explains how to determine maximum operating time based on duty cycle.

Installation

Preliminary Checks

Ensures gate specifications meet system requirements for smooth operation.

Installation of Leaf Supporting Foundation Box

Details the process of installing the foundation box for gate leaf support.

Installation

Setting Up the Gate

Covers preparing the gate guide bracket and ensuring proper alignment with the operator.

Installation

Installing the Operator

Guides on preparing and fitting the operator unit into the foundation box and connecting it.

Start-up

Adjustment of Anti-Crushing Device

Explains how to set the torque limit to prevent crushing hazards.

Adjustment of Internal Travel Stop Screws

Details how to adjust screws for precise opening and closing positions.

Start-up

Adjustment of Deceleration Ramp

Describes how to adjust the speed reduction points for opening and closing.

Angles of Opening Below 90 Degrees

Manual Operation

Maintenance

Bleeding

Explains how to remove air from the hydraulic system for smooth operation.

Related product manuals