EasyManua.ls Logo

FAAC 412 - Technical Data; The 412 Compact Operator; The Control Panel

FAAC 412
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 4
January, 2004
412 Operator And
455 D Control Panel Installation Manual
TECHNICAL DATA
T
HE 412 COMPACT OPERATOR
Parameter Measure
Voltage required
1
, VAC 115, +/–10%, 50-60 Hz 230, +6 or -10%, 50-60 Hz
Duty type Residential duty
Maximum duty cycle
2
18 cycles/hr 30 cycles/hr
Maximum leaf length, ft (m) 14 (4.3)
Maximum leaf swing, deg 110
Thrust and traction
3
, ft-lb
(Nm)
0-294 (0-400) 0-235 (0-320)
Stroke, in. (cm) 11 3/8 (29)
Rod speed
4
, in./sec (cm/
sec)
3/4 (1.9) 5/8 (1.6)
Thermal cut out, deg F (deg
C)
284 (140)
Operator dimensions,
l ´ w ´ h, in. (cm)
39 5/16 ´ 3 3/4 ´ 7 9/16
(99.8 ´ 9.5 ´ 19.2)
Operator weight, lb (kg) 14.3 (6.5)
Current draw, A 5 2
Maximum amperage draw
for accessories, mA
800 mA 800 mA
1) While the 412 Operator is capable of 18 or 30 cycles/hr, as a residential-duty operator it is not designed for
such continuous, sustained operation.

Other manuals for FAAC 412