4.6. CONNECTOR J2 - RAPID CONNECTION TO MINIDEC,
DECODER AND RP
This is used for rapid connection of Minidec, Decoder and RP
receivers (see fig. 14, 15, 16 and 17). Connect the accessory,
with the components side facing the inside of the card. Insert
and remove after cutting power.
4.4. TERMINAL BOARD J1 - ACCESSORIES (FIG. 2)
OPEN A - "Total Opening" command (N.O.): any pulse
generator (push-button, detector, etc.) which, by closing
a contact, commands opening and/or closing of both
gate leaves.
To install several full opening pulse generators, connect
the N.O. contacts in parallel.
OPEN B - "Partial Opening" command (N.O.) / Closing: any
pulse generator (push-button, detector, etc.) which,
by closing a contact, commands opening and/or
closing of the leaf driven by motor M1.
In the B and C
logics, it always commands closing of both leaves.
To install several partial opening pulse generators,
connect the N.O. contacts in parallel.
STP - STOP contact (N.C.): any device (e.g. a push-button)
which, by opening a contact, is able to stop gate
movement.
To install several STOP devices, connect the N.C.
contacts in series.
NB.: If STOP devices are not connected, jumper connect
the STP terminals and -.
CL FSW - Closing safety devices contact (N.C.): The purpose
of the closing safety devices is to protect the leaf
movement area during closing. During closing, in the E-
A-S-EP-AP-SP logics, the safety devices reverse the
movement of the gate leaves, or stop and reverse the
movement when they are released (see advanced
programming in Chapter 5.2.). During the closing cycle
in logics B and C, they interrupt movement.
They never
operate during the opening cycle. If the closing safety
devices operate when the gate is open, they prevent
the leaf closing movement.
NB.: If no closing safety devices are connected, jumper
connect terminals CL and -TX FSW (fig. 7).
OP FSW - Opening safety devices contact (N.C.): The purpose
of the opening safety devices is to protect the leaf
movement area during opening. During opening,in the
E-A-S-EP-AP-SP
logics,
the safety devices reverse the
movement of the gate leaves
. During the opening cycle
in logics B and C, they interrupt movement.
They never
operate during the closing cycle.
If the opening safety devices operate when the gate is
closed, they prevent the leaf opening movement.
NB.: If no opening safety devices are connected, jumper
connect inputs OP and -TX FSW (fig. 7).
- Negative for power supply to accessories
+ - 24 Vdc - Positive for power supply to accessories
Important: Accessories max. load is 500 mA. To
calculate absorption values, refer to the instructions
for individual accessories.
-TX FSW - Negative for power supply to photocell
transmitters.
If you use this terminal for connecting the negative for
supplying power to the photocell transmitters, you
may, if necessary, also use the FAIL SAFE function (see
advanced programming in Chapter 5.2.).
If this function is enabled, the equipment checks
operation of the photocells before every opening or
closing cycle.
4.5. TERMINAL BOARD J5 - INDICATOR-LIGHT AND ELECTRIC
LOCK (FIG.2)
W.L. - Power supply to indicator-light
Connect a 24 Vdc - 3 W max. indicator-light, if
necessary, between this terminal and the +24V supply.
To avoid compromising correct operation of the system,
do not exceed the indicated power.
LOCK - Power supply to electric lock
If necessary, connect a 12 V ac electric lock between
this terminal and the +24V supply.
N.B.:
Never put two
accessories (Plus 433 or 868,
Digicard, Digikey) in parallel
on the same decoder, but
use a decoder for every
accessory.