18
!
F
!
+
+
5.2. ADVANCED PROGRAMMING
To access ADVANCED PROGRAMMING, press key F and, as
you hold it down, press key
+:
•if you release key + , the display indicates the name of the first
function.
•if you release key F too, the display shows the value of the
function that can be modified with keys + and -.
•if you press key F (and hold it down), the display shows the
name of the next function, and if you release it, the value
that can be modified with keys + and - is shown.
•when you reach the last function, press F to exit the program,
and the display resumes showing the status of the inputs.
The following table shows the sequence of functions accessible
in ADVANCED PROGRAMMING:
ADVANCED PROGRAMMING
Display Function Default
MAXIMUM TORQUE AT INITIAL THRUST :
The motors operate at maximum torque
(ignoring the torque setting) at start of
movement. Useful for heavy leaves.
= Active = Disabled
LAST STROKE AT CLOSING:
The motors are activated at full speed
for 1 s to facilitate locking of the electric
lock.
= Active = Disabled
REVERSING STROKE:
Before opening, while the gate is closed,
the motors thrust to close for 2 s thus
facilitating release of the electric lock.
= Active = Disabled
LEAF 2 OPENING DELAY (2 s):
Enables delayed start (at opening) of leaf 2,
avoiding interference between leaves.
= Active = Disabled
FAIL SAFE:
If this function is activated, it enables a
function test of the photocells before
any gate movement. If the test fails
(photocells not serviceable), the gate
does not start the movement.
= Active = Disabled
PRE-FLASHING (5 s):
Activates the flashing lamp for 5 s before
start of movement.
= Active = Disabled
ELECTRIC LOCK ON LEAF 2:
For using the electric lock on leaf 2 instead
of on leaf 1.
= Active = Disabled
INDICATOR-LIGHT:
If
is selected, the output functions as a
standard indicator-light (lighted at
opening and pause, flashing at closing,
and off when gate closed). Different
figures correspond to the extra time
compared to normal work time (opening
or closing) when the output can be used
- via a relay - to power a courtesy light.
Time can be adjusted from to s in
1 s steps, and from
to min. in
10 s steps.
= Standard indicator-light
from
to = Timed output
CLOSING PHOTOCELLS REVERSE AT
RELEASE:
Enable this function if you want the
closing photocells to stop movement
and reverse it at release. Default setting
is immediate reverse.
= Active = Disabled
ASSISTANCE REQUEST (combined with
next function):
If activated, at the end of countdown
(settable with the next function i.e. "Cycle
programming") it effects 8 s of pre-
flashing at every Open pulse (job
request). Can be useful for setting
scheduled maintenance jobs.
= Active = Disabled
CYCLE PROGRAMMING:
For setting countdown of system
operation cycles. Settable (in thousands)
from
to thousand cycles.The
displayed value is updated as cycles
proceed.
This function can be used to check use
of the board or to exploit the "Assistance
request".
A.D.M.A.P. function:
If this function is enabled, the safety
devices operate in compliance with
French standard NFP 25/362.
= Active = Disabled
Display Function Default
Exit from programming and return to
display of inputs status.
NB.:
modification of programming parameters comes into effect immediately, whereas definitive memory storage occurs only when
you exit programming and return to gate status viewing. If the equipment is powered down before return to status viewing, all
modifications will be lost.
To restore the default settings of the programming press the three buttons +, -, F simultaneously and keep them pressed for 5
seconds.
ANTI-CRUSHING SENSITIVITY:
When operating with the gatecoder, it
controls anti-crushing sensitivity.
= Low = High.
EXTRA WORK TIME:
When operating without a gatecoder
and limit-switch, if reversing occurs, and
if the leaf does not reach its end contact
point, you can activate this function to
increase work time.
= Active = Disabled