24
Fig. 26
Fig. 27
OPEN
OTHER SAFETY DEVICES
8.3.3. Courtesy light
The courtesy light stays on for 2 minutes from the end of the
operation (not modifiable).
During the self-learning cycle the lamp flashes rapidly (on for
one second every two).
In case of an anomaly in the equipment or if the self-learning
cycle does not end correctly, the light flashes slowly (on for
two seconds every four).
8.4. CONNECTIONS
IMPORTANT: Always turn the power off before any intervention
on the card (connections, programming, maintenance).
The electrical system specifications are given in the chapter
“Instructions for the installer”.
Always separate power cables from the control cables. To
prevent any electrical interference, use separate sheaths.
The operator is equipped with a cable with Shuko plug already
wired; if using a different cable make sure to connect the earth
to the special anchoring point indicated in fig. 26 ref. A.
For the cable passage, use the arrangement located on the
back of the housing. If tubing is used, execute the slot as
shown in fig. 26 ref. B.
Carry out the electrical connections, referring to fig. 27. If
theSTOP input is not used, jumper connect the input to the
terminal . If the photocells are not used, connect the FSW input
to the -TX FSW terminal.
Input status LEDs
The status of automatic system stopped and at rest is indicated
in bold-face for each input.
LD Meaning Off On
1 Input status OPEN Not active Active
2 Input status STOP Active Not active
3 Input status FSW Safety devices Safety devices
activated deactivated
STOP