9. CONNECTIONS
9.1 Connect the power cable, as shown in figure 31, securing it with a clamp in the indicated area.
9.2 Fit the screw in the appropriate seat and tighten with washer
and nut (fig.31 ref.A).
9.3 Position the earth eyelet on the screw, add a washer and
tighten wit the nut (fig. 32 ref.A).
9.4 If you are using tube sleeves to secure the cables, make a slot
as shown in figure 32.
9.5 Screw the lamp in the appropriate lamp-holder.
9.6 Secure the operator housing using appropriate screws (fig.33).
Fig.31
Fig.32
Fig.33
To access the programming push-button, dismantle the cour-
tesy light ceiling fixture, unscrewing the appropriate screw.
Slide the ceiling fixture in the direction shown by the arrow (fig.34).
SET-UP CYCLE
During this procedure, the obstacle detection and Fail-safe
device are NOT operating.
The set-up cycle defines:
- anti-crushing safety levels during opening and closing
- deceleration points
- door complete opening and closing point
- pause time
This procedure can be carried out at any time, with the operator
in any position, by means of the set-up push-button (see different
set-up modes).
Set-up occurs with a max. force of 800N. If the force is not sufficient
to complete the learning, it can be increased to 1200N by
activating, during the 800N cycle, a second set-up procedure
(by pressing the set-up push-button again as indicated in the
different modes).
Two function logics are available on this appliance:
AUTOMATIC (TABLE 1)
SEMI-AUTOMATIC (TABLE 2)
10. PROGRAMMING