6 BLEEDING
Remove the screw in Fig. 24 ref.d from the front fitting
Remove the joint (Fig.24 ref.f) from the operator stem.
(Fig. 24 ref. g).
2.
3.
Loosen the tie-rods (Fig. 23 ref. a) and remove the metal
protective housing (Fig. 23 ref.
b).
1.
Remove the upper tie-rod and be careful with the
O-ring that must remain it its seat.
Remove all spacers, if present (Fig. 25).4.
Til t th e o p er ato r u p wa rd a s mu ch a s p o ss ibl e.
D o n o t f o r c e t h e r e a r f i t t i n g t o o m u c h .
5.
Supply the operator with power and move the stem
repeatedly, in and out, for all its stroke, until reaching a
smooth movement (Fig. 27).
After bleeding, repeat the operations described above in
reverse order.
6.
7.
TO PREVENT OIL LEAKAGE FROM THE
BREATHER HOLE, DO NOT TILT THE OPERATOR
DOWNWARD