EasyManua.ls Logo

FAAC S800H ENC - Input;Output Description

FAAC S800H ENC
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A B STP CL OP
OPEN FSW
24 VDC
Maglock
Encoder
Fig. A2
MOT DL1 DL2
1 ON ON
2 ON OFF
PIN LABEL FUNCTION
2 EASY 2 EASY 2easy BUS input for encoders (S800H and S450H only), XIB and loop detector boards
1 OPEN A N.O. Contact for total opening command
2
OPEN B /
CLOSE
OPEN B: N.O. Contact for opening of leaf 1 only
(with only one leaf the opening stops at 50% of traveling)
CLOSE (LOGIC B-C): N.O. Contact for closing command
3 STOP N.C. Contact for stop command
4 FSW CL N.C. Contact for closing safety
5 FSW OP N.C. Contact for opening safety
6 GND (-) 24 Vdc negative
7 GND (-) 24 Vdc negative
8 + 24 24 Vdc positive
9 OUT (-)
24 Vdc negative for warning lamp (DS1 SW12=OFF)
24 Vdc negative for safety TX photocell (monitored) (DS1 SW12=ON)
IMPORTANT: for UL325 compliance the negative TX photocell option must be used
10 FCA 1 Open limit switch Motor 1
11 GND (-) 24 Vdc negative
12 FCC 1 Close limit switch Motor 1
13 FCA 2 Open limit switch Motor 2
14 GND (-) 24 Vdc negative
15 FCC2 Close limit switch Motor 2
LAMP LAMP
Audio Alarm output (DS1 SW11=OFF)
Output for flashing light 24Vdc 15W max (DS1 SW11=ON)
IMPORTANT: for UL325 compliance the Audio Alarm option must be used
LOCK LOCK
Output for electrical lock, max 5A pulse (DS2 - SW 4=OFF) 12 Vac / 24Vdc
Always ON (maglock): max 1 A (DS2 - SW 4=ON) 24 Vdc
MOT1 MOT 1 Motor 1 output ( first moving motor )
MOT2 MOT 2 Motor 2 output ( second moving motor )
USB A USB Firmware upgrade input
2. INPUT / OUTPUT DESCRIPTION
A3

Related product manuals