Gate Construction
Vehicular gates should be constructed and installed in
accordance with ASTM F2200: Standard Specification
for Automated Vehicular Gate Construction.
For more information, contact ASTM at: www.astm.org
Installation
If you have any questions or concerns regarding the
safety of the gate operating system, do not install the
operator and consult the manufacturer.
The condition of the gate structure itself directly
affects the reliability and safety of the gate operator.
Only qualified personnel should install this equipment.
Failure to meet this requirement could cause severe
injury and/or death, for which the manufacturer
cannot be held responsible.
The installer must provide a main power switch that
meets all applicable safety regulations.
It is extremely unsafe to compensate for a damaged
gate by increasing hydraulic pressure.
Install devices such as reversing edges and photo
beams to provide better protection for personal
property and pedestrians. Install reversing devices
that are appropriate to the gate design and
application.
Before applying electrical power, ensure that voltage
requirements of the equipment correspond to the
supply voltage. Refer to the label on your gate
operator system.
Usage
Use this equipment only in the capacity for which it
was designed. Any use other than that stated should
be considered improper and therefore dangerous.
The manufacturer cannot be held responsible
for damage caused by improper, erroneous or
unreasonable use.
If a gate system component malfunctions,
disconnect the main power before attempting to
repair it.
Do not impede the movement of the gate, you
may injure yourself or damage the gate system as a
result.
This equipment may reach high thermal
temperatures during normal operation, therefore use
caution when touching the external housing of the
gate operator.
Use the manual release mechanism according to
the procedures presented in this manual.
Before performing any cleaning or maintenance
operations, disconnect power to the equipment.
All cleaning, maintenance or repair work must
performed by qualified personnel.
General Safety Precautions
9. For gate operators that utilize a contact sensor (edge
sensor or similar):
Locate one or more contact sensors where the risk
of entrapment or obstruction exists, such as at the
leading edge, trailing edge, and post mounted
both inside and outside of a vehicular horizontal
slide gate
Locate one or more contact sensors at the bottom
edge of a vehicular vertical lift gate.
Locate one or more contact sensors at the bottom
edge of a vertical barrier (arm).
Locate one or more contact sensors at the pinch
point of a vehicular vertical pivot gate.
Locate hard-wired contact sensors and wiring so
that communication between sensor and gate
operator is not subjected to mechanical damage.
Locate wireless contact sensors, such as those
that transmit radio frequency (RF) signals, where
the transmission of signals are not obstructed or
impeded by building structures, natural land-
scaping or similar hindrances. Wireless contact
sensors shall function under their intended end-use
conditions.
Use only FAAC MSE MO, CN60 or M60 edge sensors.
Important Installation Instructions (continued)