Do you have a question about the FAAC TM2 X R MINI and is the answer not in the manual?
Brand | FAAC |
---|---|
Model | TM2 X R MINI |
Category | Remote Control |
Language | English |
Ensures installation by qualified technicians adhering to safety directives.
Use an automatic bipolar switch with >=3mm contact opening to prevent short circuits.
The white wire must be insulated when not in use due to electric shock risk.
Illustrates the operation of pressing button A on the remote control.
Shows pressing buttons A and B simultaneously on the remote control.
Depicts a wired button or commutator used for device control.
Demonstrates the function of the SET button for configuration.
Represents the LED indicator light on the device, showing status.
Instruction to disconnect the power supply before maintenance or setup.
Indicates the action of powering up the device for operation.
Symbol indicating a short motor rotation in a single direction.
Symbol for a long motor rotation in the opposite direction.
Symbol representing a double short motor rotation.
Details the power supply voltage and frequency requirements for the device.
Specifies the power consumption of the device in Watts.
Indicates the radio frequency used for communication with the control unit.
Information about the decoder system used for signal processing.
Specifies the modulation type used for signal transmission.
The maximum number of remote controls that can be stored in the system.
Defines the maximum power capacity of the motor supported by the unit.
Specifies the acceptable ambient temperature range for device operation.
Details the physical dimensions of the control unit in mm.
States the weight of the control unit in grams.
Indicates the ingress protection rating (IP) of the device.
Demonstrates a correct sequence of button presses for motor control commands.
Illustrates a sequence that will not be accepted by the system.
Procedure to check if the open/close programming function is enabled or disabled.
Steps to enable the programming function for remote controls.
Steps to disable the programming function for remote controls.
Explains the automatic disabling of the first remote control setting after a time limit.
Procedure to set the correct rotation direction of the motor using the SET button.
Procedure to add more remote controls to the system, up to 15.
Process to delete a specific remote control from the unit's memory.
Method to clear all stored remote controls using another remote.
Method to clear all stored remote controls using the SET button.
Using the remote control to ascend the connected device.
Using the STOP button to interrupt the current command.
Using the remote control to descend the connected device.
Control active only while the contact is closed, with 3-minute timeout.
Short impulse activates output for a set time; press again to stop.
Procedure to switch between Dead Man Mode and Latching Mode.
Details on wiring the commutator to the control unit for up/down functions.
How a wired button operates the unit in a step-by-step manner (up, stop, down, stop).
Automatic awning opening when sunlight exceeds a threshold.
Automatic awning closing when sunlight drops below a threshold.
Automatic awning closing during wind alarms and lockout period.
Steps to associate the TM2 X W sensor with the control unit.
Steps to remove the TM2 X W sensor from the control unit's memory.
Procedure to associate an anemometer sensor with the control unit.
Procedure to remove an anemometer sensor from the control unit's memory.
Enables testing of wind and sun functions and radio communication.
Procedure to test the wind sensor's functionality by simulating wind conditions.
Procedure to test the sun sensor's response to varying light intensity.
Procedure for temporarily storing a remote control for specific tasks like factory setting.
Manufacturer's declaration that the product complies with EU directives.