EasyManua.ls Logo

FAAC TM2 X R MINI - Safety Instructions; Professional Installation and Safety Compliance; Short Circuit Prevention Measures; White Wire Handling Safety

FAAC TM2 X R MINI
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TM2 X R MINI 20 A4518_6H82_Rev.A
NL
L
N
230 V 50 Hz
6
2
1
3
2
1
3
3
1
2
5
4
6
SAFETY INSTRUCTIONS
ELECTRICAL CONNECTIONS
• Only professional technicians must perform installation, complying with all safety
instructions, especially those regarding electrical connections.
• To avoid short circuits, arrange an automatic bipolar switch with opening distance
of the contacts of at least 3 mm before the circuit.
• If not used, the white wire must be insulated. It is dangerous to touch the white
wire when the motor is powered.
Commutator
Common
Down
Up
Button
1 BROWN - PHASE
2 BLUE - NEUTRAL
3 WHITE - OPTIONAL
WIRED SWITCH
4 GREEN - DOWN
OUTPUT
5 YELLOW - UP OUTPUT
6 RED - COMMON
Connection for optional wired switch
EN