9 Performance test
First time water fill, see Chapter 8.3.
Check all connections for water leakage.
Check if the fan, mounted at the top inside the fire, is running.
Check if the remote control is functioning at the desired distance (max. 8m)
o If needed, move the receiver to a different position in- or outside the construction
(see fig. 4.2).
The receiver is placed at the back inside the Engine and has a cable length of 1,4m.
Replace fuel bed see Chapter 6.
Replace front glass see Chapter 5.1 or 5.2.
Perform a final functional check.
10 Maintenance
10.1 Maintenance frequency
Cleaning water sump, air filter and replacing transducers.
Commercial use: every three months.
Domestic use: once a year.
Cleaning mesh filter and replacing in-line filter.
Commercial use: once a year.
Domestic use: every second year.
!! The maintenance interval depends on the water quality and/or the running hours and therefore
can differ from the above mentioned.
10.1.1 Cleaning water sump
!! Always press the mains switch to the OFF position and disconnect the power supply see fig. 4.0.
!! Never use abrasive cleaners.
Remove the front glass see Chapter 5.1 or 5.2.
Remove the fuel bed see Chapter 6.
Disconnect the ‘fill cap’ by turning it clockwise see fig. 5.0-L and 7.0.
Disconnect the 2 connectors, located on the right side of the water sump see fig. 7.1.
Release the 2 clips on both sides and remove the nozzle see fig. 7.2 and 7.3.
Gently lift up the water sump without spilling any water see fig. 7.4.
Remove the transducers and empty the water sump.
Put a small amount of washing up liquid into the sump, and using a soft brush to clean the
sump. Also clean the transducers, including the discs underneath the cone. Remove the cone
by turning it clockwise.
When cleaned, thoroughly rinse the water sump with clean water to remove all traces of
washing up liquid.
Clean the nozzle with the a soft brush and flush out thoroughly with water.
Reverse the steps above to reassemble.

Other manuals for Faber e-MatriX 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Faber e-MatriX 800 and is the answer not in the manual?

Faber e-MatriX 800 Specifications

General IconGeneral
BrandFaber
Modele-MatriX 800
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals