Manual e-MatriX 800
--------------------------------------------------------------------------------------------------------------------------------------
9 < < < <
4 Installation instructions
4.1 Preparing the fire
Ensure that all packing items are removed.
Remove the transport screw on the front see fig. 1.0.
Remove the front glass and store it at a safe place see Chapter 5.
Remove the fuel bed and store it at a safe place see Chapter 6.
4.2 Placing the fire
For a proper functioning of the fire, always ensure that the fire is levelled.
4.1.1 Floor standing
Place the fire at the right position and fix it on the wall see fig. 1.1.
4.1.2 Hanging on the wall
The fire can be hanging on the wall with the optional wall bracket see fig. 1.2a, 1.2b and
dimensional drawing in Chapter 13.6.
4.3 Control box
!! Place the Control box at an accessible location behind the service door.
See Chapter 13.5 and 13.7.
4.1.1 Electric connection
Use the supplied extension cable to connect the Control box to the Engine.
Lead the DC cable, inside the Engine, to the Control box and connect it.
- Max. cable length from the center of the fire to the left 1,5m.
- Max. cable length from the center of the fire to the right 1,0m.
Connect the supplied mains lead.
4.1.2 Water connection
This appliance is equipped with the following overflow protections:
o Electromechanical valve in the Control box which is sent by an overflow sensor in the
water tank.
o Absorption valve in the Engine that kicks in when the water sump has an
unexpectedly overflow see fig. 5.0-K.
Connect all parts according flow diagram see fig. 5.0.
A = mains water F = mesh filter 1 = safety clips (11x)
B = ½ or ¾ connector G = in-line filter 2 = in-line filter brackets (2x)
C = ¼ 1m pipe H = control box 3 = elbows (4x)
D = ball valve I = ¼ 1,5m pipe
E = to be cut from ¼ 1m pipe J = e-MatriX engine
Place the water filters at an accessible location in correct alignment, there’s a “flow”
direction marking on both filters and Control box.
!! Carry out a performance test see Chapter 9 and check all connections for water leakage before
placing the fuel bed and front glass.

Other manuals for Faber e-MatriX 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Faber e-MatriX 800 and is the answer not in the manual?

Faber e-MatriX 800 Specifications

General IconGeneral
BrandFaber
Modele-MatriX 800
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals